TELKOM NIKA Indonesia n  Journal of  Electrical En gineering   Vol.12, No.6, Jun e  201 4, pp. 4491 ~ 4 4 9 9   DOI: 10.115 9 1 /telkomni ka. v 12i6.548 8          4491     Re cei v ed  De cem ber 2 4 , 2013; Re vi sed  Febr uary 21,  2014; Accept ed March 6, 2 014   Test Data Analysis on Voltage Regulation of Proportion  Relief Valve      Pei Weichi*, Cao Fu kai, Zhao Shuzho ng  Heb e i Un ited U n iversit y   46  Xin h u a  Roa d T angsha n 0 630 09, He bei,  Chin a T e l: + 86031 52 592 16 6   *Corres p o ndi n g  author, e-ma i l w h ich _pa y@ 163.com       A b st r a ct   T he mi niat ure  reform des ig n w a s to imp r ove  the volta ge reg u lati on  of regul ar val v e and   prop ortion al v a lve. La bVIEW  w a s used to  d e vel op C A T   vo ltage r e g u lati o n  of pr oporti on  reli ef valv e w i th   electro hy drau l i c prop ortion al  control an d vi sual i n stru men t. T he content of t he pressu re adj ustment of   prop ortion al r e lief va lve  w a s intro duce d  fr om diffe r ent a ngl es a nd t h e  steady-state.  T e st on v o lt ag e   regu latio n  of pr oporti on rel i ef  valve w a s an al y z e d . T he sa mplin g dat a w e re process ed a nd an aly z e d  o n  a  time   d o m ai n a nd  fre q u ency d o mai n   b a sis. R e late c oncl u si ons are mad e  by  a nalys is on   curre nt  li ne arit y,  steady-state pr essure, an d pr essure- adj ustin g  del ay.  Systematic  methods  and refe r ence s  are provi d e d  f o r   the deve l o p m e n t of other valv es to improve t he  functio n  an d the system of  proporti on al valve.      Ke y w ords : pro portio n  reli ef valve, volta ge re gul ation, L abVI E W ,  CAT        Copy right  ©  2014 In stitu t e o f  Ad van ced  En g i n eerin g and  Scien ce. All  rig h t s reser ve d .       1. Introduc tion  As on e of the  most im po rtant control  co mpone nts i n   hydrauli c   circuit, the main  function   of relief valve is to adjust the pre s sure of hydraul i c  circuit [1]. By u s ing the test  system an d CAT   on voltage re gulation of proportio n  relie f valve,  the content of voltage re gulatio n on pro porti on   relief valve was sel e cte d  to analyze the  data on a time domain a nd frequ en cy domain ba si s in   orde r to  get t he  result of  voltage regul ation, del ayin g an d p r e c isi on, all  of whi c ca n p r ovi de  referen c e s  for manufa c tu rers to p r od u c e p r opo rtion a l valve [2,  3], and provi de guid a n c for   manufa c turers to enh an ce  the quality a nd fun c tion o f  propo rtional  valve. It is  also h e lpful f o use r s to u s e  prop ortion al  valve better and to  achi eve better d e velopme n t and ap plication of  electro-hydra u lic propo rtio n. Referen c e s  ca also be provid ed  for other e l ectro - hyd r aul ic  prop ortio nal valves.       2. Design an d Inno v a tion Plan of Test Platform   In ord e r to  achieve the te st req u irem ents about  p r o portion relief valv e in the exp e riment,   a spe c ial h a r dware syste m  wa s req u i r ed to te st t he voltage regulatio n [4]. The hydra u lic   prin ciple s  sho w n a s  Figu re  1.  To test  pilote d propo rtion  relief valve,  the ra nge  of p r essure valu wa s 0 10 M P a and   the moving speed of hyd r aulic  cylinde r on a test  ri g  was  0.02 ~0. 05m/s. Th e p r opo rtion  reli e f   valve in the  experi m ent  sh ould  be  controlled  un der  no rmal  pre s sure a n d lo w di sch a rge.   Acco rdi ng to   the p r ima r y p a ram e ter, th e  high es t  pressure  wa set   up a s  6MPa,  and th highe st  flow rate was  10 20 L/mi n. The origin al relief valve and pre ssure ga uge s were repl ace d  by  piloted propo rtion relief valve and pressu re se n s o r  accordin g to QCS003B. See Figure 2.      Evaluation Warning : The document was created with Spire.PDF for Python.
                               ISSN: 23 02-4 046                     TELKOM NI KA  Vol. 12, No. 6, June 20 14:  4491 – 4 499   4492   Figure 1. Sch e matic Di ag ram of Hydra u lic System           Figure 2. Ref o rm Desi gn Diagra m  of Pre s sure Ad j u st ment Platform of Proporti onal Relief Valve      3. CAT o f  Pressur e  Adju stmen t  Platform of Prop ortional Relief Valv e   Combi ned  with virtual tech niqu es, the adju s tme n t platform  wa s esta blished a  comp uteri z e d  system with data colle ctio n and ele c tric system. The target and th e pro c e ss we re  controlled  by digital  comp uter a nd the  data colle ct io n of pa ram e ter  su ch a s  p r essure a nd fl ow  were processed so that the  test can  be a c hieve d  qui ckly and pre c isely [5, 6].    3.1. The Desi gn and Mod e l of Hard w a re Sy stem  As the  pressure  value  fro m  the valve   port i n  the  te st shoul d b e  mea s u r ed,  diffusion  silicon pressu re se nsor  HG 2000  wa s sel e cted o n  t he basi s  of the requireme nt for hardware a n d   measurement  pre c isi on. During th e dat a colle cti on,  the pre s sure  sho u ld not  be collecte d   too   fast. Con s ide r ing both  pre c isi on an d cost, dat a coll ection  ca rd  PCI-91 12 wa s ch osen fro m   ADLINK compatible with LabVIEW [7].  To re alize th e switch  of I/V from 4 ~~ 2 0 m A to 0 + 5V, circuit am plification  wa desi gne to be compact size, stabl e perform ance,  low power  cons um ption and extensibility .  See Figure  3.  LM324  ampli f ier, pre c isi o n  resi stor  and  capa cito r were d e si gned  for switch a d justin g   board, whi c h   ca n be use d   to amplify sign al,  filter   noise a n d  switch  I /V fro m  the  sig nal   from  p r es su re  s ens o r Evaluation Warning : The document was created with Spire.PDF for Python.
TELKOM NIKA   ISSN:  2302-4 046     Test Data Analysis o n  Voltage Regulati on  of Propo rtion Reli ef Valve (Pei  Wei c hi)  4493     Figure 3. Sch e matic Pictu r e of I/V Circui t Switch and  Amplification       3.2. Soft w a r e  Sy stem De sign  Software te st  platform with  virtual instru ment wa s d e s ign ed by u s i ng rel a ted p r ogra m ing   softwa r e, and  CAT can b e  used to the test re qui rem ent su ch a s  items, content s and met h o d s,  whi c can  proce s s the  dat a from th co ntrolled,  and  test an d cont rol b o th the  steady-state  a nd  transi ent process if the  rela ted output informatio n wa s set in advan ce [8].        Figure 4. Flow Dia g ra m of Modula r ization De sig n       LabVIEW  wa s u s ed  to d e sign an d p r og ram ‘Te s t mo d u larity’, whi c h  ca n divide th e main   prog ram i n to  four  sub - mo dule s  such a s  test, contro l, data coll ection and  dat a analy s is. S e e   Figure 4.    1) In the main prog ram, first, the monit o ring  a nd the  signal inp u t of the test point and      were set, and  reflux control l er wa s ad de d to moni tor the flow rate from the hydra u lic platform   2) Se con d , two wave  controllers  were a dded  to  be  co nne cted  with  the entran c of every   modula r  p r og ram  so th at the re gula r  hyd r auli c   te st ca n be d one,  an d the no rmal   pump  and val v can be controlled  (pre ssu r from adju s tment  pla tform and the fl ow  can  be m onitore d)  with out  the enga gem ent of the pro portion al relie f valve.  Evaluation Warning : The document was created with Spire.PDF for Python.
                               ISSN: 23 02-4 046                     TELKOM NI KA  Vol. 12, No. 6, June 20 14:  4491 – 4 499   4494 3) The th ree  tests for  ste ady-state, dy namic  re spo n se a nd p r e s sure adj ustin g  delay,  and data coll ection an d di gital filter loading we re de sign ed as  su b-mo dule s , and we re set i n  the   front main bo ard a s  button s  so a s  to coll ect data by pressing the b u ttons.  4) Data  re cord, data pre s e r vation, re cord displayin g  and re sult pri n ting we re d e sig n e d   as the  seco nd level m o dule by u s in g the butto n  cont rol  so  as to  reali z e  the re co rdi ng,  pre s e r vation  and pri n ting o f  the data.  5) Fa ult alarming si gnal  wa s set in the pro g ra m int e rface by u s i ng the uni qu e pro g ra fault system  to stop the  susp end  featu r e. Wh en the r e is  som e thi ng wron g wit h  the hydra u l i c   system, data   coll ectio n  card   or software   pr og ram m ing  system ,the program  will  be  sto p ped  immediately [9, 10].      4. Test  and  Data Analy s is on Refo rm Design  of Pres sure  Adjus t ment of Propor ti onal  Relief Valv e   Pilot type ele c tro - hydrauli c  prop ortio nal  re lief valve DBE10-30B -10 0 YM wa ch ose n  a s   the test obje c t can be a c co rded  with any  feature of no rmal valves.     4.1. Stead y - state Con t rol  Pressur e  – Current Lin e a r it y  Test and  Data  Analy s is  The be st way to measure the  perf o rma n ce  an d the pressure a d ju stment of a   prop ortio nal relief valve is t o  test the lin e a rity , the feature of th e pre s sure  output  and the  cu rre n input u nde r t he n o rm al hy drauli c   syste m  co nditi on.  The p r e s sure  adju s tment  can  be te ste d  by  analyzi ng the  linearity of the valve.  1) Te st Meth ods  (1) A s  the hy drauli c   syste m  wa s wo rkin g unde r lo w p r essu re a nd  small flow, the  highe s t   pre s sure of the propo rtion a l relief valve  shoul be 6 M Pa and the  effective con t rol of the inp u curre n t sign al  for the prop o r tional control  amplifier was 400mA.  (2) Afte r the  pre s sure va lve wa s reco rded,  a  current  sig nal was sent between  the  starting  curre n sig nal   and   the rated  current si gn al  of the  p r op ortional  am pl ifier. Repe at  the   pro c e ss and measure  the pre s sure  of  e a ch cu rrent  value  while th e pro p o r tiona l relief valve  wa workin g stea dy-state, re co rd the com p le te cycle of P I curve com posed of posi t ive sample a n d   negative sam p le.  (3) Co mbin e d  with  cu rve s , a g r ou p o f  data was  colle cted  accordin g to the  above  pro c e ss, an d the linearity curve of stead y-stat e pressure -current can be an alyzed and  comp are d   with the ideal  linearity of propo rtion a l re lief valve,  the n  the linea rity of pressu re  adju s tment can   be co ncl ude d .   The analy s is  formula of ste ady-state  con t rol for propo rtional relief valve is:    % 5 . 3 % 100 linearity  max A L                                                                                          (1)    In formula  max L --- The maxi mum deviatio n  betwe en st eady-s tate co ntrol curve an d its best fitting  line  A ---- D-value o f  the rated cu rre nt and initi a l curre n Becau s e  of t he n onlin earit y of initiation  of pr essu re a d justme nt  for the  p r opo rtio nal relief  valve, the starting value  of linear current sho u ld b e  set as the  lower d ead  point by using  MATLAB to get the best fitting cu rve thro ugh  lea s t sq u a re meth od o f  best app roximation.  2) Ori g inal  Data and Calib ration Analy s i s  of Pressu re -cu r rent Te st  A com p lete  cycle of li nea ri ty of steady-state  co ntrol  o f  pre s sure-cu rre nt for  prop ortional  relief valve b y  using MAT L AB to get the best fitti ng curve th rou g h  three lea s t square metho d s of  best ap proxi m ation. See Figure 5.    Evaluation Warning : The document was created with Spire.PDF for Python.
TELKOM NIKA   ISSN:  2302-4 046     Test Data Analysis o n  Voltage Regulati on  of Propo rtion Reli ef Valve (Pei  Wei c hi)  4495     Figure 5. The  Linearity Cu rve of  Steady-state Pre s sure-current       It is sho w e d  in Figu re 5 th at pre s sure zero d ead  zo n e  app eared b e twee n 0 10 0mA in   the propo rtio nal am plifier,  and  no p r e ssure  wa sh o w even the   curre n t drive   wa s a dded  to  th e   prop ortio nal v a lve. It is su g geste d that th e area  s h ou ld b e  pa ss e d  as  q u i ck ly as  po ss ib le W h en   the input  cu rrent wa 100 250mA, the  pre s sure  sig nal data  a c q u isition  point  wa s fluct uate d , it  is sh owed tha t  nonlinea rity exists in the signal du ring t he pre s su re a d justme nt.      Table 1. Te st Data of Pre s sure -current Li nearity   0 400mA   For w a r d sampling  test  (No.)   Input  signals  (mA)   Output p r essure  value  (mPa)   0 400mA   Rever s e sample  test  (No.)   Input  signals  (mA)   Output p r essure  value  (mPa)   1 0  0.00  400  5.67  2 25  0.00  380  5.20  3 50  0.00  350  4.75  4 75  0.00  330  4.46  100 0.10  300 4.21  125 0.20  290 4.11  150 0.40  260 2.97  175 1.07  240 2.66  200 1.50  215 2.20  10  225 2.00  10  200 1.55  11  250 2.80  11  180 1.70  12  275 3.50  12  170 1.25  13  300 3.97  13  150 0.60  14  325 4.20  14  135 0.37  15  350 4.66  15  100 0.10  16 375  4.90  16  50  0.05  17 400  5.51  17  0.00      The maxim u m derivatio betwe en  stea dy-state  co ntrol cu rve a nd  the be st fitting line i s   240 2 50mA,  and the data  and form ula can be con c lu ded from T a b l e 4 and Fo rmula (1 ).    % 5 . 3 % 5 . 2 % 100 0 400 240 250 % 100 linearity  max A L     It is showed f r om th e ab ove that the te st  wa s en gag e d  un der the  steady-state  condition   of prop ortion al relief valve .  The linearit y of pres su re -cu r rent was  2.5%, which is less tha n  the  stand ard  line a rity erro r 3.5 % . It is al so  showed th at th e pe rforman c e of p r o portio nal relief valv wa s stable, a nd  the   no nlin earity  e rro r was normal,  th e de sig n  of th e p r essu re  a d justin g pl atform  w a s  re as o nab le  a n d  th e ad ju s t men t  pr ec is io n   w a s   c o r r e c t. T h e pr op o r tio n a l  re lief va lve  c a n be   use d  in a pra c tical  situatio n with a c tual  data  and a n a lysis to  correction e r ror  compen satio n   in   orde r to bette r improve the  perfo rman ce  of propo rtion a l relief valve.    Evaluation Warning : The document was created with Spire.PDF for Python.
                               ISSN: 23 02-4 046                     TELKOM NI KA  Vol. 12, No. 6, June 20 14:  4491 – 4 499   4496 4.2. Stea d y - S tate  Pre s s u re-Curr e nt Tes t   Anal y s is on Ti me Dom a in and  Freq u e nc y   Spectr u a) Methods  The  pre s sure  load  in th e h y drauli c   cylin der s hould  b e  kept to  be   1, the p r e s su re i n  the  prop ortio nal relief valve should be adj u s ted to 5.5, and 400mA was add ed to the pro portio n a amplifier.   The d a ta  wav e  was  re co rd ed by the  test  software  sy stem, and th cha ngin g  line a rity of  steady-state  pre s sure time domain wave wa s analy z ed.  The data fro m  the colle cti on ca rd  wa s anal yzed by MATLAB. The frequ en cy spe c tru m   wa s prog ram ed, and the  F FT wa s e nga ged imm ediat el y. To analy z e the  pro portional reli ef valve   unde r the adj ustment p r e s sure, and to  analyze the s pectrum di stri bution of pre s sure  sig nal  and  fluctuation, n o ise a nd pressure fl uctuati on in the hydraulic  system.   b) Te st Analysis  (1) Tim e  Dom a in Analy s i s   The  rate of  sampling  card   wa s 40 960S/ s  throug h p o int sam p ling. I t  is sho w ed  i n  Figu re  6 that the time domai n wave was  wi thin 0.05s, a nd the sa mp ling point s were fro m  178 88  to1999 1.  It is  sho w ed  from t he Fi gure  6  that t he p r e s sure  curve   colle cting from the   adju s ted   pre s sure val ue of 5.5MP a  in the  pro portion al  reli ef valve wa s not a line a r but a  curve  with  irre gula r ity a nd flu c tuatio n, whi c su gge st ed that  unde r th steady-state  load  co ndit i on,  hydrauli c  cyli nder  woul d p r odu ce p r e ssure di stur ban ce to the pip e line sy stem  to overcome  the   work lo ad. An d wh at is m o re, the hydraul ic cy lin der  wo uld be  delaye d  whil e produ cing  pre s su re   disturban ce   or d e layed  b y  the extern al di stur b a n c e. It can  be  se en l a rg fluctuation  in  the  sampli ng of 1 8000, 18 800,  and 19 200 of  the curve tim e  domain.            Figure 6. Analysis of Time -domain  Wave form       (2) Po we r Spectral  Den s ity-Freque ncy A nalysi s   The math em atical inte gral  of stable  ra ndom  sign al can not  be co nverge ju st as  the   spe c ific  statistical ave r ag e value can n o t be sh o w e d  the reflect ed ran dom signal as the  set   sign als, a s  a  result, functio n  in the frequ ency  d o main and  p o wer sp ectral den sity  function sh o u ld   be u s ed to  sho w  the av erag e spe c tral ch ara c te ristics. The p u rpo s of freque ncy do main   cha r a c teri stics is to re co rd both FFT  function in t he frequ en cy domain an d  powe r  spe c tral   den sity function.  Spectrum d e n sity wavefo rm is th e mo st  impo rtant  para m eter fo r testin stationary  rand om si gn al and it can  clearly di spl a y the dist rib u tion of discrete stationa ry random  sig nal,  machi ne or  fluid vibratio n signal. Sp ectru m   den sity waveform analysis i s  easy to find   brea kd own, noise a nd vibration pro b lem  during the o p e ration.   The ene rgy spectrum an al ysis in the time domai n waveform data  acqui sition p o int wa see n  in the   Pic 37  wh en  the pressu re  value was  5.5MPa. To te st the a c tual  vibration  sign al,  bilateral p o wer sp ect r al d ensity analysi s  woul d be u s ed in the M A TLAB time frequ en cy toolbox,  and it is sho w n in the Fi gure 7 a s  th e Bilateral Spectrum, wh ose  sampli ng  frequen cy was  200 Hz, only u n ilateral p o wer sp ect r al de nsity of 0 100Hz will be analyzed.  Evaluation Warning : The document was created with Spire.PDF for Python.
TELKOM NIKA   ISSN:  2302-4 046     Test Data Analysis o n  Voltage Regulati on  of Propo rtion Reli ef Valve (Pei  Wei c hi)  4497     Figure 7. Analysis G r aph of  Spectru m  De nsity Wavefo rm      It is sho w ed  from th cu rve of p o wer spectral d e n s ity that within  the p r e s sure  sign al o f   finite sa mplin g poi nt d a ta, the m a ximu m spe c trum   pea wa at  10Hz, a n d  its amplitu de  was  740; anoth e large r  pe ak  was at 50 Hz, and its amp litu de wa s 50 0; the third larg er pe ak  wa s at  80Hz, a nd it s am plitude   wa s 4 50, h o w ever,  othe r po wer spe c tral de nsity  were di stri bu te d   spa r sely, and  their amplitu de wa s bet we en 100 a nd 4 00.  It is con c lud e d  from the ab ove that unde r the  low  pre s sure an d sm a ll flow co ndition, the  pre s sure fluctuation from  the pre s sure  adjustin g  sy stem of the  prop ortio nal relief valve was  focu sed to  a  large  extent  on the lo freque ncy, a nd vibratio and lo w-f r eq uen cy pre ssure  pulsation were sho w e d  in the hydra u lic  system  a nd test syste m  b e ca use of disturban ce.     4.3. Pressur e -adju s ting  Dela y  Test  1) The o reti cal  analysi s   Hypothe si s t e st of  avera g e   differe nce t  wa eng age d with  the t w o di screte  st ationary  rand om sequ ences, an d their n o rm ality and inde pen den ce were t e sted. Th ere  is no  significant   differen c e bet wee n  sam p lin g value and t heoretical val ue.  Relative a nal ysis  wa s to d e scrib e   whet her li nearity exis ts  between two variables .  In  broa sen s e ,  two statio nary rand om  seq uen ce  ) ( n x  and  ) ( n y ,their cro s s correl ation  coeffici ent wa s:    2 1 1 0 2 1 0 2 1 0 ] ) ( ) ( /[ ) ( ) (  N n N n N n xy n y n x n y n x Z                                                                 (2)    To evaluate t he rel a tive function of the t w o rand om seque nces, an d observe the  chan ge   dire ction wh e t her  p o sitive correl ation,  n egative  corre l ation o r   zero correlation.  If the chan g e   dire ction of  ) ( n x ) ( n y  is th sam e , the  coeffici e n t co rrelation  will  be  z>0;  and if th ch ange  dire ction of  ) ( n x ) ( n y  is th e o ppo si te, the coefficient correlatio n will  be  z<0;  and  if there i s  n o   cha nge di re ction of  ) ( n x ) ( n y  , the  coeffici ent correl a tion will be z=0.        Table 2. Mea s ureme n t Dat e s of Pre s sure-adj ustin g  Delay  Input curren t   (mA)   Output p r essure  value  (mPa)   Dela y  time    (s 0.100  0.10  0.056   0.150  0.40  0.061   0.175  1.07  0.060   0.200  1.50  0.054   0.225  2.00  0.049   0.250  2.80  0.050   0.275  3.50  0.051   0.300  3.97  0.037   0.375  4.90  0.053   0.400  5.51  0.047   Evaluation Warning : The document was created with Spire.PDF for Python.
                               ISSN: 23 02-4 046                     TELKOM NI KA  Vol. 12, No. 6, June 20 14:  4491 – 4 499   4498 2) Te st analy s is  In the te st,  a group  of  control  cu rrent  sig nal were sent from  the compute r  to the  prop ortio nal  relief valve, a nd timing.  Ob serve  the  current val ue  an d p r e s sure  value  and  record   and mo nitor t he time whe n  ch ang es from the cu rre n t input to th e output of t he pressu re,  and  then analy z the two ran d o m  numeri c al  seq uen ce s.   The ori g inal d a ta of pre ssu re adju s ting d e lay test wa s sho w n in Ta b l e 2.  3) Visu alization analy s is of  3D sp ace   Visuali z ation  of 3D sp ace, prog rame by MA TLAB, can be  clea rly and directly display the  internal  relati ons b e twe e n  current in put , pressu re o u t put and pressure-adju s tin g  delay into the  3D  sp ace. It is  sho w e d  in  Figu re  8 tha t  after the  op eration  of th e test  syste m , the p r e s sure   adju s tment of propo rtional  relief valve was not  stabl e  when the ini t ial current a d justme nt wa cha ged, an d becau se the  overflow  wa s not fully  finished when th e hydra u lic p u mp was  started  with low pressure, the initial time for pressu re adj ust m ent wa s del ayed long er,  however, whrn  the system  was op erate d  n o rmally, the p r essu re a d ju stment delay wa s sh orten e d         Figure 8. Visualization An alysis of 3 D  Space          Figure 8   sho w s Visuali z ation a nalysi s   of 3D  spa c e  for the  cu rrent i m put, pressu re outp u t   and pressu re  adju s tment d e lay.  It can be co nclu ded fro m  the above  analysi s  that  there a r e si gnifica nt cha nge s in   curre n t input  and p r e s sure  output in the  prop ortio nal  relief valve, a nd the  coefficient co rrelatio n   is po sitive, which  signifie d  that the cha nging  spe ed  and the p r e s sure value  are in the sam e   dire ction  eve r y time in  th e current  adj ustment  sam p ling  point, a nd the  p r essure  adju s tme n delay is short  at the speed  of ms, whi c can b e  achie v ed within 10 0ms.   Some  current adjustment and  we ak  pressure voltage f o llower  still  exist in the test, whi c sho w s that p r essure adj ust m ent delay  e x ists in  the  proportio nal  reli ef valve duri n g the test, a n d   the p r oble m  i s  that  the  pul sation  interf e r en ce   in th hydrauli c   system an d el ectromag netic  and  noise distu r b ance co uld b e  respon sibl e   for the nonlin earity of the test re sult.       4. Conclusio n   The pressu re  adjustin g  de lay platform of pr oportional relief valve is a reform  of self- desi gn a nd  st udy with l o w-co st combin e d  with  el e c tro  hydra u lic  proportio nal  co ntrol a nd visu al  instru ment of  CAT. The content  of the pre s sure a d justment of  prop ortio nal relief valve was  introdu ce d from differe nt angle s  a nd t he ste ady-s ta te, dynamic  a nd del ay ch a r acte ri stics in  the   pre s sure a d j u stment  we re teste d  a n d  analy z ed,  a nd the  sampl i ng d a ta  were processe and  analyzed  on  a time  domai n an d frequ e n cy d o main  b a si s, an d the   referen c dat a were a c q u ired  and the con c l u sio n  of the pressu re a d ju stment  cha r a c teristi cs we re rea c he d.      Referen ces   [1]    Z hang  Gong,  Yu L a n y i ng. R e vie w   a nd D e velo pm ent T r end of E l ectro- h y dr au lic Pro p o r tiona l Va lve .   F l uid Mac h in er y . 2008; 36( 8): 32-3 7 Evaluation Warning : The document was created with Spire.PDF for Python.
TELKOM NIKA   ISSN:  2302-4 046     Test Data Analysis o n  Voltage Regulati on  of Propo rtion Reli ef Valve (Pei  Wei c hi)  4499 [2]    Z eng Yis h a n , Xi a Yo ngs hen g. Deve lo pme n t of H y dra u l i c  CAT  Compre hens ive E x peri m ental T able Coal Mi ne Mac h in ery . 200 5; 25(5): 30-3 1 [3]   Z heng   Sh eng li.   Reform  of El e c tronic C ontro l  S y st em of  Det a cha b le  H y dr a u lic E x per imen tal Pl atform.  Coal Mi ne Mac h in ery . 200 6; 27(3): 126- 12 7.  [4]    Z hang  Yu nan.  App licati o n  of  Prop ortion  V a lve  of Overfl o w in Devic e   Used  in  H y dr a u lic Pr essur e   Station.  C o al  Te ch no l o g y . 200 7; 26(7): 21-2 2 .   [5]    Hu Junk e, He Guohu a. Desi g n  on the Perfo rm ance T e st Exp e rime nt Platform of the Hig h Pressur e   and Bi g F l o w  P r oporti ona l Dir ection al Valv es Machine T o o l  & Hydraul ics . 200 6; 1(1): 94- 95.   [6]    Yao C h e n g y u,  Z hao J i n g y i.  Desig n   and  P r actice o n  E l e c trical C ontro l  an d Hy drau li c Systems  of   Hydra u lic Stati on of T e st-bed.   Machin e T ool  & Hydrau lics.  2 010; 38( 8): 46- 48.   [7]    Yan Ji do ng, Y ang Z h ih on g. D y namic  testin g s y stem a nd  i t s data transm i ssion for  QCS 003  h y dr aul ic   exper imenta l  pl atform.  Chines e Journ a l of Co nstruct Ion Machin ery.  200 7; 5(2): 220- 22 3.  [8]    Pan W e i, Che n  Guiming. T he  Appl icatio n of Virt ual Instrum ent T e chniqu e in H y dra u lic M easur ements.   Machi ne T ool  & Hydrau lics.  2 001; 3(3): 1 23- 125.   [9]    Jian g Cha o , Xu W ubin. Des i gn of Inst rume nt Control S y s t em Based on  LabVIEW .   TE L K OMNIKA  Indon esi an Jou r nal of Electric al Eng i ne eri ng.  2013; 1 1 (6): 3 423- 343 8.   [10]    Ding Ji an jun,  Sun Ch ao. A Rapi d Detect ion S y stem B a sed o n  La b V IEW  and Microcomp u ter T E LKOMNIKA Indon esi an Jou r nal of Electric al Eng i ne eri ng.  2013: 1 1 (6): 3 066- 307 1.     Evaluation Warning : The document was created with Spire.PDF for Python.