Internati o nal  Journal of P o wer Elect roni cs an Drive  S y ste m  (I JPE D S)  V o l.  7, N o . 1 ,  Mar c h  20 16 pp . 22 5 ~ 23 I S SN : 208 8-8 6 9 4           2 25     Jo urn a l  h o me pa ge : h ttp ://iaesjo u r na l.com/ o n lin e/ind e x.ph p / IJPEDS  A Shunt Active Power Filter fo r 12 Pulse Converter Using  Source Current Detection Approach       Ra jesh  T*,  Ni rmalkum ar  A * *   *Departm ent  of  Ele c tri cal  and  E l ectron i cs Eng i ne ering,  IN FO Institute  of  Engin eer ing, Kovi lpal a y a m , Coim batore   Tam il Nadu , Ind i a   **Karpagam Co lleg e  of  Engin e ering,  Co imbator e Tamil Nadu, I ndia      Article Info    A B STRAC T Article histo r y:  Received Oct 14, 2015  Rev i sed  D ec 16 , 20 15  Accepte Ja n 10, 2016      A shunt  Active  Power Filter (APF)  with  current  detection at th e source side   is considered  as  a closed-loop s y stem  from the view of th e w hole power   distribution s y s t em , which is  expect ed with  better h a rm onics filt ering   performance  co mpared with co nvention a current detection methods such as   load cu rrent detection  and open loop  con t rol. This pap e r in troduces an   efficient source  current d e tection  m e thod (direct)  control sch e m e  to m itigat the grid  curren t  harmonics gen e rated b y  th e twelve pulse  co nverter . Th proposed s y stem uses Contro l Rect ifier (12 –pulse conver t er) which   efficiently  regu lates th e DC voltage  b y   var y ing  the  angle of each 6 pulse  converter. Moreover, the propo sed sy st em uses three winding transformer   which eliminates the harmonics during  equal  angles switching  at each six   pulse conv erter  which  in turn   sim p lifies th e o p erat ion of  the   SAPF. The   proposed s y stem is si mulated  in MATLAB SIMULINK to  evalu a te  the  performance of  the proposed  s y stem. Keyword:  1 2  –pu lse co nver t er  Activ e p o wer  filter  Co n t ro l rectifier   Cu rren t d e tectio DC vo ltag e   Lo ad  cu rren detectio O p en  l o op  contr o l   Copyright ©  201 6 Institut e  o f   Ad vanced  Engin eer ing and S c i e nce.  All rights re se rve d Co rresp ond i ng  Autho r Raj e sh T,    Depa rt m e nt  of  El ect ri cal  and   El ect roni cs  E n gi nee r i n g,   INFO In stitu te o f   Eng i n e ering,  Kov ilp alayam ,  Co im b a to re, Ta m il Nad u ,  India  Em a il: raj e sh tsch o l ar@g m a il. co     1.   INTRODUCTION   The  Sol i d -St a t e  p o we r el ect r oni c  co n v ert e r s  are  ge ner a l l y  use d   f o r  p r o v i di ng  c ont r o l l e po we r t o   electrical  lo ad lik e p e rson al co m p u t ers; p r i n ters; h ea ting ,   v e n tilatio n, and  air cond itio nin g   (HVAC) syste m s ;   adjusta b le s p ee dri v es, elevat or dr ive ,  a r furnaces  a n d arc   welde r s. Th e s e  loa d s a r e c o ns idere d  as  nonlinear  loads  because of the  fact  that they pull harm onic curre nts from  th e ac m a ins along  with their active powe dem a nd.  In a d di t i on,  wi t h  u n b al ance d c o n d i t i on  of t h ree - phase system s, they draw ne utral currents i n  e x cess.  The i n ject e d   h a rm oni cs, rea c t i v po wer   dem a nd , i m bal a nce, a n d  l a r g neu t ral  cu rre nt po se m o re l o a d   o n  t h e   u tility p o w er syste m  eq u i p m e n t,  raise th power system  lo s s es, an d thu s   deg r ad e t h p o wer system  efficien cy.    Co m p en satio tech n i qu es lik e p a ssi v e   o r  activ e power  filtering  (APF) are h e lpfu l in  im p r ov ing  t h line side powe r quality for the purpose  of c o m p lyi ng with harm onic guideline  standa rds like IEEE 519-1992  [1 ]. Po wer quality  issu es can  b e  reso l v ed with  p a ssi v e  filters, alth oug h, p a ssi v e  filters h a v e  th eir o w dem e ri t s ;  whi c h com p ri se o f  t h e so urce i m pedance s  de pe ndency, parallel / series  reso na n ce, agi n g o f  pa ssi ve   com pone nts,  unm anagea ble  filter current s  and  reactiv e  power t h at coul d be  gene rated [2].  Owi ng t o   sem i cond uct o r devi ce de vel o p m ent ,   t h e APF  t e nds   t o  bec o m e   hi ghl y  ho pe ful   c o m p ensat o s o l u t i o n [3] [ 6 ] .   B a sed o n  t h e  i n st al l a t i on t ech ni q u es, t h e A P F co ul be  clas sified as a se ries APF, a  hybrid APF, a nd  a shunt APF.  The se ries APF is always connecte d  in se ries to  th e grid   b a y tran sfo r m e r. Al o n g   with   v o ltage  p r o t ectio n   for lo ads, it co u l d   also  yield  g ood  h a rm o n i cs cu rren t filtering with  a v a riety o f  co n t ro l tech n i q u e [7 ]–[9 ]. No n e t h eless, th e availab ility  o f  a series-co n n e cted  tran sform e r hu g e ly in creases th e co m p lex ity   Evaluation Warning : The document was created with Spire.PDF for Python.
                        I S SN 2 088 -86 94  I J PED S  Vo l. 7,  No 1,  Mar c h  2 016   : 2 2 5  –  23 22 6 i n v o l v e d  wi t h  desi g n   a n d dep l oym ent   i n  pra c t i cal   appl i cat i ons , w h i c h re d u ce  t h e use of  t h seri es   A P F .   T h e   h ybrid  APF is in trodu ced   with  th e tho ugh t o f  its econ o m ic feasib ility to   m e rg e th e u s e o f  an  APF and  a PF.  By th is, th e cap acity requ iremen t o f  t h e APF cou l d  b e   re duce d  t o  a  dra m at i c  l e vel  [10] –[ 1 3 ] .  B u t ,   f o r m o st   n o rm al v o ltag e  lev e l co nd ition  and   n o rm al  cap acity requ ire m en t, th e h ybrid  APF is still to o  co m p lex  to  b e   tak e n  in t o  con s id eration .  In  this situ atio n ,  th e sh un t APF is yet th m o st e x ten s i v ely e m p l o y ed  k i n d  to   han d l harm onics c u rrents. It is  di rectly connect ed in s hun t between  t h g r id  source an d lo ad s,  with ou t any   m odi fi cat i on t o  t h net w or ks a l ready   prese n t ,   whi c h i s  eas ier fo r i n stallatio n or cu t off in  t h e practical field .   Also , th e aim   o f  th shun t APF system  is t o   b e  ab le to b a lan ce th e h a rmo n i cs curren t   fro m  th e load  sid e , t h u s  ensuring  th at t h ere is no   d i stortio in  th e curren t  i n  th e so urce si d e         Fi gu re 1.   The  B a si Sh unt  A c tive Powe r Fil t er Architecture      Fig u re  1  illu strates th b a sic  Shu n t  activ e po wer  f ilter arch itectu r e con s i s tin g   o f  grid,  VSI,  APF and  l o ad c u r r e n t  d e t ect i on ba sed  cont rol  sc hem e . Thi s  c o nve n t i onal  sy st em   m a kes use  o f  t h e t h ree  pha se  di o d e   bri dge  rect i f i e r  desi g n  re ga rd ed as  no n l i n ea r l o a d  p r o d u ci ng  u n re g u l a t e d  out put . B u t  i n  case, i f  t h e i n dust r y   n eeds a regu lated  ou tpu t  fo an y of th e applicatio n s , th is  co nv en tio n a l syste m  d e sig n   may n o t  b e  a su itab l opt i o n.  I n  ad di t i on, i f  t h out put   of t h unc ont rol l e rect i f i e r i s  gre a t e r t h an  8 0 0  V ,  t h i s  sy st em  i s  not  agai n   ap pro p riate. Th u s , con t ro lled rectifier  will be a d e si red choice for  h a nd ling  th e abov e m e n tio n e d   scen ari o s.  Co n t ro lled rectifiers are usually e m p l o y ed  in   h i gh   po wer ap p lication s , p a rticu l arly  at m e d i u m   v o ltag e  (M V)  lev e ls b ecau s o f  h i g h e reliab ility, rob u s t n ess, lower co mp lex ity, an d lesser  po wer losses.  In   ad d ition  to th e v a riab le  p o wer fact o r , th e ch ief  d i sadv an tag e  is the h a rm o n i cs p r o d u c es resu lts in  a po wer  q u a lity  issu e at  th co nv erter ac-sid e  [1 2 ] , [14 ] [15 ] The  basi c co nt rol  sc hem e  of  t h e sh u n t  AP F  coul be t h e l o ad c u rre nt  de t ect i on ki nd Hence ,  f r o m   th e pu rv iew of th e who l e pow er  distribution system  and  with re spect  t o  th e so urce cu rren b e ing  th co n t ro targ et, th e contro l sch e m e  with  lo ad  cu rrent d e tecti on is  always treated as an  ope n l o op sy st em , wi th t h cont rol  t a r g et   bei n g i n di rect l y  cont r o l l e d,  a s  sh ow n i n  Fi g u re  1.  The i m port a nt  o b ject i v e of t h i s  pa pe r  i s  t h in trodu ctio n   o f  an  efficien t clo s ed  lo op  con t ro lling  sch e m e  fo r th e purpose o f  eli m in ati n g  th g r id  curren t   harm oni cs pr o duce d  by   t h e   t w el ve p u l s c o nve rt er.        2.   PR OPOSED   1 2  –PU L SE  C O N V E R TER  FOR    R E GU LA TES DC   V O LTAGE BY   V ARYING  THE ANGLE S   Th p r o p o s ed   syste m  arch itectu r e is illu strated  in  fi g u re  2 .  It ch iefly consists o f   1 2   pu lse con v e rter  mad e  o f  con t ro lled  rectifier, th ree  phase three  winding trans f orm e r, activ e power filt er and the ass o ciated  co n t ro l scheme. Th e pro p o s ed  syste m  is b u ilt with  a  th ree-wi n d i n g  tran sform e r (s tar/tap p e d  star/delta) and   one S A PF c o n n ect ed t o  seco nda ry  t a ps whi c h pr o v i d es fi l t er si de vol t a g e  reduct i o n ,  w i t hout  t h e nee d  for a   hi g h  ba nd wi dt h st ep d o w n  t r ansf o r m e r. Thi s  aut o —t ra ns f o rm er t y pe con f i g urat i o n l i m i ts t h e vol t a ge ra t i ng of  th e SAPF switch e s, th ereb y,  in creasi ng th switch i ng   frequ en cy  li m it. Th is arran g e m e n t  help s i n  m i t i g a tin th e n e t am p - turn with in  t h e tran sfo r m e r win dow area  fo the curre nt ha rm onic co m ponents that is ge nerated  by each 6-puls e  conve rter, al ong with  t h e net  harm onics balanced by  t h e SAPF.  In   o r d e r to   b e   ab le to  con t ro l th e SAPF, a so urce d e tection  con t ro l sch e me h a s b een   broug h t  in to   u s e in  th is  work wh ich  is  ex p l ain e d   clearly in  th e section s   b e low.          Gri d L o ad  cu rr e n t C ont r o l   schem e   N on lin ear lo a d   Unc o nt r o l l e rectifie r   DC  lin k APF   VSI Evaluation Warning : The document was created with Spire.PDF for Python.
I J PED S    I S SN 208 8-8 6 9 4     A Shu n t  Active  Po wer Filter f o 1 2  Pu lse Con verter  Using   S o u r ce Cu rrent Detectio n App r oa ch   (Ra j esh.  T)  22 7 Impor t ance of  Contr o l Recti f ier in the Pr oposed Syste m   The t h ree  p h a s e f u l l y  cont r o l l e bri dge  c o n v e r t e has  been  probably t h e m o st extensively use d   po we r el ect r o n i c con v e r t e r t o  be  em pl oy ed  i n  t h e  m e di u m  t o   hi g h   p o we r  ap pl i cat i ons.   Three   phase  ci rcui t s   are prefe rre d i n  the case  of l a rge  powe being i n vol v ed . T h e co nt r o l l e r ect i f i e r can  of f e r co nt r o l l a bl out put   dc  volta ge in a  single unit in  place  of t h ree   pha se a u to tra n sform e r and a  diode  bri dge  re ctifier. T h e c o ntrolled  rectifier is g o t  b y  su bstitu tin g th e d i o d e s o f  t h e un con t ro lled  rectifier with th yristo rs. C o n t ro l o v e r th e o u t p u t   dc v o l t a ge i s  g o t  by  ap pl y i ng  a cont r o l  o n  t h e con d u ct i on i n t e r v al  of eac h  t h y r i s t o r. T h i s   m e t hod i s  refe rre d t o   as phase c o ntrol and c o nve rt ers a r e also  kno wn  as “p h a se  co n t r o lled conv er ters”.    Signific ance  of twelve  pulse   convert er  and three  winding  transformer   In t h i s   prese n t e d arc h i t ect ure ,  t w el ve  pul se  co nverte r and the three  wind i n g t r an sf orm e r pl ay  a  si gni fi ca nt  r o l e  i n  t h ove ral l   per f o r m a nce o f  t h e  sy st em . For  i n st a n ce, t w el ve- pul se  co n f i g urat i o n c o m p ri ses   o f  two  sets  o f  co nv erters con n ected  in   series  as illu strated  i n  Figu re 2.    Th e resu ltan t   ac cu rren t is ob tain ed   b y  th e su m  o f  the two Fourier se ries of the sta r  connection  (eq u at i o 1) a n del t a  co nn ect i on t r ans f orm e rs ( e q u at i o 2):     i √ I cos ω t cos 5ωt cos 7ωt  cos 11ωt .     ( 1 )     i √ I cos ω t cos 5ωt cos 7ωt  cos 11ωt .       ( 2 )     i 2 I cos ω t  cos 11ωt  cos 13ωt  cos 23ωt .      (3 )           Fi gu re  2.  The   pr o pose d  s o urc e  cu rre nt  det e c t i on  base d S A PF  Arc h i t ect ur     The  seri es  o n l y  has  t h e   harm oni cs   of  o r der 12 1 . T h harm oni c  cu rre nt s  o f   o r ders   6 1 (W ith  k o d d ), i . e. 5t h,  7t h,  1 7 t h 1 9 t h , et c., ci rc ul at es bet w ee n t h e t w o c o nve rt er t r ansf o r m e rs but  does  n o t  ent e r s  t h e   ac n e twork. The resu ltin g  lin e cu rren t  for th e twelv e -pu l se  rectifier is as sh o w n  in  Figu re  3 ,  wh ich  is similar   to a sinusoi d al wave form  than earlie r l i n e cu r r ent s The i n st ant a ne ou s dc  v o l t a ge al so  bec o m e s sm oot her  wi t h   th is conn ectio n. Th e twel v e -pu l se  was  g o t   with  a 30 ° phase - shi f t bet w een  the tw o sec o nd ary  t r an sf orm e rs.         , ,    6- pulse conver t er                                                T h r ee- phase thr e e-winding tr ansform e Pri m a r Secondar y   6- pulse  conver t er           3- phase supply    PWM  gener a tor        Cur r e nt Contr o l Loo p DC- voltage Regulation        Contr o l Schem e      Evaluation Warning : The document was created with Spire.PDF for Python.
                        I S SN 2 088 -86 94  I J PED S  Vo l. 7,  No 1,  Mar c h  2 016   : 2 2 5  –  23 22 8     Fig u re  3 .  Th e resu lt lin e cu rren fo r th e t w elve-pu l se  rectifier      2 . 1 .  Co ntro lling  Scheme  of  the  Pro p o s ed Sy stem  Th e in ten tion   o f  th is wo rk  is fo cu sing  on  th e co n t ro lling sch e m e  to  b e  ab le to  co n t ro l th e activ p o wer filter.   Th e im p o r tan t  o b j ectiv e is co m p en satin g   t h e grid  cu rrent. Th e sign ifican t op eration   o f  th co n t ro lling  sche m e  is th e eli m in atio n   of th distu r b a n ces  or  h a rm o n i cs in th g r id curren t  th at is g e n e rated   b y   the non linear load (twelve pulse conv erte r) by m eans of injecting of cu rren t fro m   APF. Th is way, th is  i n ject i o n o f  cu rre nt  has t o  be  i n  a cont rol l e d m a nner t h r o ug h ef fi ci ent  cont rol  schem e . The sect i on b e l o pr o v i d es a  di sc ussi o n  a b o u t  t h e t w o co n v en t i onal  co nt r o l l i ng m e t hod s an d i n fl ue nced  b y  t hose co n v e n t i onal   co n t ro lling  tech n i q u e s, an  effectiv e con t ro llin g  sch e m e  is  p r o p o s ed  wh i c h  is cap ab le  o f   o v e rco m in g th li mitatio n s  of t h e co nv en tion a l co n t ro lling  tech n i q u e s.      2.1.1. Conventional  Controll ing Sc hemes    Th is section   o f fers t o   d i scu s ab ou t th conven tio n a l con t rollin g  techn i qu es th at are  reg a rd ed as th i n fl ue nce  fo r t h pr o pose d  c o nt r o l l i ng sc he m e .   1.   Lo ad  cu rren detectio n  m e th o d   2.   O p en  l o op  contr o l m e th o d     2. 1. 1. 1.   Load Current De tection  Me thod  The co nt r o l  l o op a r chi t ect u r e  of t h e c o n v e n t i onal  L o ad c u r r ent   det ect i on m e t hod i s  i l l u st rat e d i n   Fi gu re  4.    The   gene rat i o of  c o m p ensat i n g  si gnal  by  t h e l o a d  c u r r e n t  det e c t i on m e t hod  i n vol ves t h ree  co nt r o l   stages,  which a r e; re fere nce e x traction, c u rre nt  con t ro l,  and   th e PW M [3 ],   [6 ],  [11 ] [ 13 ].          Fi gu re  4.  The  c ont rol  l o o p  a r c h i t ect ure  o f  t h e  co nve nt i o nal   Loa d  c u r r ent   d e t ect i on m e t hod       Wh ere id an d iq are i n stantan e ou s activ e  a n d reactive  c u rrents  re spectively, ( V   An V     den o t e s t h e  ch ange  i n   dc l i n k  vol t a ge an re fere nce  dc l i n k  vol t a ge res p ec t i v el y ,   id1h a n diq1h  refe rs   to   th e first h a rm o n i activ cu rren t of p o s itiv sequ en ce  and   h a rm o n i c reactiv e curren t   o f  po sitiv e seq u e n ce.    Owi ng t o  t h f eedbac k  o f  l o a d  cu rre nt , t h del a y  t h at  i s  prod uce d  i n  t h e r e fere nce si g n al s and/ or t h e   o r i g in al inj ected  curren t  d e lays h a v e  an  effect o n  th APF co m p en sation  qu ality, p a rticu l arly at ti m e s wh en  the s w itching  freque ncy is low.  These  ki nds of c ont rolling techni ques  a r known as i n direct m e thods . As a  resu lt, t h e co mp ensated  m a in s curren t  THD can   b e   g r eater th an  th e stand a rd s allowed .  Few so l u tio ns h a v e   b een   p r esen ted fo r so lv i n g  a  p r ob lem o f  th is k i nd Man y  trad ition a l APF tech n i qu es mad e  u s o f  l o w-p a ss  filters (LPF) for ex traction  of th e cu rren h a rm o n i cs an d   classical co n t ro llers fo r th e curren t co n t ro l lik e PI or  hy st eresi s  [1 4] . Thi s  res u l t s  i n  harm oni c m i s-cancel l a t i on beca use o f  pha se shi f t s  a nd re fer e nce t r acki ng  erro rs wh ich in tu rn   d e teriorat e filtering   p e rfo rm an ce.      To  VSI       to    Transform a tion   (Load  current)    (Grid  voltag e )   LP F LP F  Transform ation   PWM  generator       PI   Evaluation Warning : The document was created with Spire.PDF for Python.
I J PED S    I S SN 208 8-8 6 9 4     A Shu n t  Active  Po wer Filter f o 1 2  Pu lse Con verter  Using   S o u r ce Cu rrent Detectio n App r oa ch   (Ra j esh.  T)  22 9 2. 1. 1. 2.   Open  L o op Control Method  The fundam ental co m p ensation  prin ci pl e o f  t h e ope n-l o o p  co nt rol l e d shu n t  SAP F  fo r  a nonl i n ea r   lo ad  is illu strated  in  Fig u re  5 .  By u n d e rstan d i n g  th n o n l in ear lo ad  op eratin g  co nd ition s , th e fi ring  d e lay  angl e,  an d t h e  l o ad  cu rre nt   whi c h i s  s u pp ose d  t o   be  ri p p l e  f r ee, t h n t h ha rm oni c c u r r ent  t h at  has  t o   be  injecte d  at the  PCC can  be c o m puted . This  c u rrent ca ncels  the res p ectiv e nt h harm oni s u p p l y   cu rre nt . These   fav o ra bl e com p en sat i ng  har m oni c curre nt  vect o r s can  be  deci de d by  fi xi ng t h e co rrect   m a gni t ude s an d p h ase - shift angles of the harm oni c contents . A Phase Lo c k e d  Lo op ( P LL )  i s  em pl oy ed for t h e p u r p o se o f   syn c hron izing th e co m p en satio n  pro cess. Th d c -link   cap acito vo ltag e  is con t ro lled  to   ob tain  a p o wer  b a lan ce  b e tween  th e filter and   th e m a in s b y  mean s o f  a separa te co n t ro l loo p . It is co n t ro l l ed  at a lev e l j u st fo avoi ding  ove m odulation a f ter the  add ition  of the  harm oni c m odulating s i gnals.          Fi gu re  5.  The  f u n d am ent a l  co m p ensat i on  pri n ci pl of  t h o p en -l o o p  c ont r o l l e d s h unt   SA PF        W i t h  a n  aim  to  gene ralize the  algorithm  and  acco m p lish  current harm onic com p ensation on  t h e basis   of t h e k n o wl e dge  o f   I  , and α under eve r y possi ble loadi n g conditio ns; table s  of  ha rm onic m odulating  sig n a l info rm atio n  are bu ilt,  o f f-lin e. Two   k i nd o f   h a rmo n i c tab l es are n e ed ed : tab l es for th e am p lit u d e m   and tables  for the  pha se a n gles θ . Th ese tab l es are u tilized  as l o o k - up tab l es in which  th eir d a ta is  interpolated  for ge ne rating a n y neces sary  values of  m and  θ ,  whi c h rem ove s t h e sel ect ed  harm oni c o r de rs   as illu strated  i n  Fi g u re  5 .  To   ach iev e  t h e requ ired  ou tp u t   vo ltag e  fro m  th e 12  pu lse co nv erter, th firi ng   d e lay   angle of each  six pulse converter has to  be  varie d  in  a continuous m a nne r. Howeve r, this offline c ont rolling  schem e  i s  not  pr o poe fo r t h dy nam i c fi ri ng  del a y  an gl e vari at i o of  t h e 1 2   pul se  c o n v e r t e r. T h abo v men tio n e d fact o r  d e teri o r ates  th e ov erall p e rfo r m a n ce of the APF in th d y n a m i c v a ryin g   co nd itio n.    2. 2. Propose d  Source   Curre nt Detec t ion Method   On th e b a sis  o f  th e inv e stigatio n   o f  th e afo r em en tio n e d  co n t ro lling   sch e m e s, th e sou r ce curren t   d e tectio n  sch e me h a s b een  presen ted. Th propo sed  sch e me p r o v i d e s th e b e n e fits o f   b o t h  th e trad ition a l lo ad   cur r ent   det ect i on a n d o p en l o o p  c ont r o l  sc hem e s and,  at the sam e   time, elim inat es t h eir limitat i o n s. Th pr o pose d  c ont r o l  schem e  i s  sim p l e r i n  st ruc t ure a nd  d o es  not   need  a ha r m oni cs ext r act i on al g o r i t h m .  The   pr o pose d  c ont r o l  schem e  i s  deri ve d ba sed  o n  t h e em pl oy m e nt  o f  t h vect or  res ona nt  ( V R )  co nt r o l l e r, a nd i t  i s   got  t h ro u gh a  seri es o f  t r ans f orm a t i ons t h at  are ap pl i e d t o   t h e co nve nt i o n a l  l o ad cu rre nt  det ect i on sc he m e  is  sho w n i n  fi gu r e  6.     The co nt r o l  schem e  chi e fl y   com p ri ses of t h ree  part s:  p h a se-l oc ked l o o p  (PLL ),  dc l i nk  vol t a ge   regu latio n, and cu rren t con t rol lo o p . Th e PLL lin k  is h e lpfu l for track i ng th e real-tim e   p h a se in fo rm atio n   o f   gri d  v o l t a ge  VGa bc  fo o n l i n e ad ju st m e n t  of t h reso n a nt  f r eq ue ncy  of  res o nant  c ont rol l e rs;   dc- vol t a g e   regu latio n  is ap p lied fo r m a i n tain ing  th dc v o ltag e ; a n d  the cu rre nt c ont rol lo o p  f o rm s the core  part t o   i m p l e m en t h a rm o n i cs filterin g .   Mo du latin g sign al  Lo ad ing  co nd itio n     , ,   Lo ok -u p t a bl es Mo du latin si gnal s   PW gene rat o r   To  VSI   PLL at PCC   Evaluation Warning : The document was created with Spire.PDF for Python.
                        I S SN 2 088 -86 94  I J PED S  Vo l. 7,  No 1,  Mar c h  2 016   : 2 2 5  –  23 23 0     Fi gu re  6.  The   pr o pose d  c o nt r o l  sc hem e  usi ng t h e  em pl oym ent  o f  t h vect or  res o nant   (V R )  co nt r o l l e r       Al so,  t h e   gai n  ef fect   of  p u l s e wi dt h  m odul at i on c o nt r o l l e VS K  is ind i cated  as un ity fo r th p u rp o s o f  sim p l i fyin g  th e an alysis, with  its in flu e n ce in  th e co n t ro ller tak e n  in to  co n s i d eration .   Th e lin in du ctor is the  syste m  co n t ro p l an t, and  it cou l d   b e   realized   as      P s  1 sL  R   (4 )     Whe r L  and  R  are the  equivale nt induct ance  and resistance  of L , respectively.  Th e cu rren t con t ro ller is  n e cessary for th cu rren con t ro l lo op , and  t h e VR co n t ro ller is u s ed   for  each control s c hem e  that is  discusse d in  this pa per.   The VR controller kee p s all the adva ntages  of the   reso na nt  c ont r o l l e r, l i k e  ef fi ci ency  i n  c o m put at i o n a n d z e ro steady-state errors  fo r t h e re gul at i o of  t h e a c   sig n a l. Also , in  co m p arison  with  th e PR co n t ro ller, th VR co n t ro ller  h a s an  am azin g  feature o f  selectiv ity.  As s h ow n i n  [ 1 9] , t h e  ex pre ssi on  f o r  VR   co nt rol l e r c o ul be   gi ve n as     VR s k  ss R  L  s  n ω   (5 )     Whe r k   is th gain  of t h e co n t ro ller, and    i s  t h e co rres p on di n g   reso na nt  f r eq uency .     In  add itio n  t o   th is, th VR co n t ro ller t h e co n t ro p l an t tak e s in t o  acco u n t , an d its go od  selectiv ity   rend ers it q u ite ap t for th e selectiv e APF,  with  wh ic h the restricted de vice capac i t y  coul d be rea s o n abl y   placed for com p ensating the m o st ha rm ful harm onics, and  the   potent ial  resona nce in power distributi on  n e two r k s  cou l d  b e  avo i d e d   with  flex i b ilit y. Selectiv e h a rm o n i cs co mp ensatio n  co u l d  b e  realized   b y  th im ple m entatio of cascade  VR controllers VR  i n  t h e c u rre nt  co nt rol  l o o p .   Su bscri p t  n  de not es t h e sel e ct ed ha rm oni cs o r de r.  As s h ow n i n   Figure 3,  VR  i s  t h e supe r posi t i o n  of eac h VR  c o nt r o l l e r, wi t h  e v ery  c ont r o l l e r  t une d o n   one  harm oni cs o r d e r.   In th is co nd ition ,  t h referen c e track i n g ab ility o f  t h e cu rrent co n t ro l l o op  i n  Fi g u re  3  cou l d   b e   d e fi n e d as    is i  s  P s . VR s 1 P s . VR s  P s .V R s 1 P s .V R s   (6 )          ,      ,    VSI     PI        PW m odul at or   PW      Grid  Filter  12 -P ul se  Co nv erter Based   Non Linear  L o ad  Evaluation Warning : The document was created with Spire.PDF for Python.
I J PED S    I S SN 208 8-8 6 9 4     A Shu n t  Active  Po wer Filter f o 1 2  Pu lse Con verter  Using   S o u r ce Cu rrent Detectio n App r oa ch   (Ra j esh.  T)  23 1 3.   RESULTS  A N D  DI SC US S I ONS     The pe rf o r m a nce of t h pr o p o se d so urce c u rre nt  det ect i o n  based  SA PF f o r a  12 -P ul se  C o n v ert e r i s   si m u lated  in   MATLAB/Simu lin k en v i ronmen t u s ing th e Si m  Power - S y st em  t ool bo x.  The  res u l t  i s  e v al uat e d   base d o n  t h e st eady  st at e and t h e dy nam i c perf orm a nce of  t h e pr o pose d  s y st em  and t h e achi e ve d si n u s o i d al   current  with m i nim a l THD  obtained at t h grid.    Param e t e rs such as gri d  vol t a ge (V Gab c ),  gri d  cu rre nt  ( I Ga bc) ,  St ar con n ect ed sec o nda ry  out pu t   cu rren t (ISab c ), Delta conn ected  s econd ary  o u t p u t  cu rrent (IDab c), Filter  curren t  (IFab c o f  t h e prop o s ed  sy st em  are eval uat e d t o   dem onst r at e i t s  pr o p e r f unct i o ni n g .   M o re ove r, T o t a l  Harm oni Di st ort i o (TH D o f   g r i d  cu rren t is  an alyzed   for  determin in g  t h p o wer  q u a lity at g r i d  sid e   3. 1.  1 2   – P u l s e C o n v erter  Re sul t Val i d ati o n o f  Pr op ose d   Sys t em    Th e resu lt ob tain ed  sh ows th e sig n i fican ce of th e 12 -pu l se co nv erter u s ed in  th e p r op osed  system . It  is clearly observed from  th r e sul t s  t h at ,  f o r   equal  fi ri ng  de l a y  angl es  o f  e ach  6- p u l s e c o nve rt er,  f o r e x am pl (A _1= α _ 2 =3 ) as s h o w n i n   Fi gu re  7 a nd  ( A _ 1 = α _ 2 = 0 ° )   as sh ow n i n  Fi gu re  8. T h e ac hi eve d   gri d  cu rre nt   IGa b c wa vef o r m wi t hout   c o m p ensat i on fo r bot sce n ari o a r e near   si n u soi d al  wi t h  m i nim u m   THD.   T h e   THD  o b tained  for the  firin g  delay  an gles (A _1= α _2= 30 °) a nd ( A _ 1 = α _2 =0°)  is 1 0 . 89 % and 6 . 07%  respect i v el y .    Thi s  i s  due t o  fact  t h at , 1 2 - p ul se co nve rt er  red u ces t h ha rm oni c or ders  suc h  as 5t h ,  7t h, 1 7 t h 1 9 t h ,  etc. Hen c e, on ly li m ited  in j ection   b y  the  SAPF is enou gh  t o  m a in tai n  th e op tim al o u t pu t.      A 1 =a2 = 30 A 1 =a2 =                       Fi gu re  7.  The  r e sul t  f o r  eq ual   fi ri n g   del a y  an gl A α 30° of  1 2 - p ul se c o nve rt er      Fi gu re  8.  The  r e sul t  f o r  eq ual   fi ri n g   del a y  an gl A α 0 ° of  1 2 - p ul se c o nve rt er       3.2. Different Firing  Delay Angles   The ex pe ri m e nt al  resul t s  o b t ai ned f o r eac h 6 - p u l s e co n v ert e wi t h  di ffe rent  fi ri ng  del a y  angl es   with ou t co m p en sation ,  fo r exa m p l e (A_1 =53 ° α _2= 1 0 °) a nd ( A _1= 1 0 °;   α _2= 53 °) as sh ow n i n  Fi g u re  9 a n d   10 re spectively .   Respective Star co nnected s econda r y out put  current wa veform  (ISabc)  and  delta connected  seco nda ry  out put  cu rre nt  w a vef o rm s (IDa b c) an d m o reove r, g r i d  v o l t age V G abc i s  sho w n f o r b o t h  t h scenari o s i n  Fi gu re 9 ( d )  an Fi gu re 1 0  ( d ) .  It  i s  cl earl y  observe d f r om  t h e resul t s  t h at , f o vari ed  fi ri n g  del a angl es , t h obt ai ned T H D wi t h o u t  com p ens a t i on i s  hi gh Fo r i n stan ce, th e THD  ob tain ed   with   firing  d e lay   Evaluation Warning : The document was created with Spire.PDF for Python.
                        I S SN 2 088 -86 94  I J PED S  Vo l. 7,  No 1,  Mar c h  2 016   : 2 2 5  –  23 23 2 angl e of  ( α _1= 53 °;   α _2= 1 0 °) and ( α _1 =10 ° ;   α _ 2 = 53°)  is 23 .2 8% and  20 .7 5% r e sp ectively. Th is in cr ease in  THD is  becaus e  of the  im p act of the  ha rm onic orde rs s u c h  a s  5t h, 7th, 11t h,  13th, 17t h, 19th  etc.      5 3 ° 1 0 °   1 0 ° 5 3 °                   Fi gu re  9.  The  r e sul t  f o r  di f f er ent  fi ri ng  del a y  an gl es  A 53° α 1 0 ° withoutco m p e nsation of  1 2 - pul se  co n v ert e r   Figu re 1 0 T h e   res u lt  f o r dif f e r ent firin g  dela y   angles   A 10° α 5 3 ° without co mp ensat i on of  1 2 - pul se  co n v ert e r       3. 3.  E v al ua ti o n   o f  Af ter C o mpens a ti on   The e x perim e ntal res u lts for each 6-pul se conver ter  with  diffe re nt firing delay  angles a f ter  com p ensation, for  (A_1= 53°;  α _2= 10 °) a n (A _1= 1 0 °;   α _2=5 3 °)  as sh own  in   Figu r e   11   an d 12   r e sp ecti v ely.    Du e to th v a ried   firing   d e lay  an g l es, th e ob t a in ed THD  with ou t co m p en satio n  is  h i gh . Thu s , co m p en sati o n  is  requ ired . Th e resu lts sh ow the in j ected  waveform  (IF abc) for  harm onic minimizati on. For instance, t h e THD  o b t ain e d  after co m p en satio n with  fi ring  delay an g l e of  ( α _1 =53 ° α _ 2 = 10 °) a n d ( α _1 =10 ° α _2= 5 3 ° )  i s   3. 03 % and  2. 7 6 % res p ect i v el y .  Thi s   m i nim i zat i on i n  TH D  i s  achi e ved m a i n l y  due t o  i n ject ed cu rre nt  IFa b whi c h c o m p ensat e s t h harm oni o r de rs s u c h  as  5t h,  7t h ,   1 1 t h ,  1 3 t h 17t h,  1 9 t h  et c.                     Evaluation Warning : The document was created with Spire.PDF for Python.
I J PED S    I S SN 208 8-8 6 9 4     A Shu n t  Active  Po wer Filter f o 1 2  Pu lse Con verter  Using   S o u r ce Cu rrent Detectio n App r oa ch   (Ra j esh.  T)  23 3 5 3 ° 1 0 °   1 0 ° 5 3 °             Figu re 1 1 T h e   res u lt  f o r dif f e r ent firin g  dela y   angles   53° 1 0 ° af t e rco mpensa t i on of  1 2 - pul se  co n v ert e r   Figu re 1 2 T h e   res u lt  f o r dif f e r ent firin g  dela y   angles   10° 5 3 ° af t e rco mpensa t i on of  1 2 - pul se  co n v ert e r       4.   CO NCL USI O N   Thi s  pa per  pr o pos ed a n  effi ci ent  so urce c u r r e nt  det ect i on  b a sed S A PF  fo r a 12 -P ul se C o nve rt er. T h e   resul t  i s  e v al u a t e based   on  t h e st ea dy  st at e an d t h e  dy nam i c perf orm a nce  of  t h e  p r op ose d  sy st em . T h e   per f o r m a nce o f  t h e sy st em   has be en e v al uat e base d o n  t h e a ngl es  ( α _1 a nd  α _2 )  of t h e t w el ve  pul se  conve r ters. Three sce n ari o nam e ly ( α _1=  α _2 ), ( α _1   α _2 ), a n d s u dde n c h an ge i n  s w i t c hi n g  a ngl e s  ha v e   b een ev alu a ted in  t h e sim u latio n and  t h e correspo n d i ng   resu lts are  o b t ai n e d.  It is  ob serv ed   fro m  th resu lts  that during equal angle scenario,  be t t e r TH D i s  obt ai n e base d o n  t h e p h as e shi f ting  of the three  pha s e three   wind ing  tran sfo r m e r u s ed  in   th e propo sed  syste m . Ho we ver ,  dur ing  d i ff er en t an g l e co nd itio n  at th 12  pu lse  con v e r t e r,   t h e THD  gene rat e at   t h e gri d  si de has bee n   m i nim i zed  us i n g   p r o p o se d SAP F . The   dy nam i p e rf or m a n ce of  th pr opo sed syste m  h a s al so   b e en  an alysed   b y  sudd en   v a r i ation   o f  t h e 12   p u l se  conv er ter   angl e i n   whi c h  t h e t i m i ng respo n se  of t h pr op ose d  sy st em  i s  obse r ve d t o  be si g n i f i cant .  Thu s , t h pr o pos e d   syste m  clearly  satisfies th IEEE  519 -19 9 2  po wer qu ality  st an d a rd .       REFERE NC ES   [1]     M.F. McGranag han and D.R.  Mueller ,   D esigning harm onic f ilters for ad just able-spe ed drive s  to com p l y  wit h   IEEE-519  harm o n ic  lim its”,   IEEE Trans. Ind. Ap pl. , vol. 35 , no . 2 ,  pp . 312–318 Mar./Apr. 1999.    [2]     H. Akagi, “New trends in act ive filters for power condition i ng”,  IEEE T r ans. Ind. Appl. , vol. 32,  no. 6, pp. 1312– 1322, Nov./Dec. 1996.    [3]     Bhattachar y a   an d C. Chak raborty , “A shunt active pow er  filter  with enh a nced  performance u s ing ANN-based   predic tive  and  a d aptiv e con t roll e r s I EEE Trans. Ind. Electron . , v o l. 58 , no . 2 ,  pp 421–428, Feb .  2 011.    Evaluation Warning : The document was created with Spire.PDF for Python.
                        I S SN 2 088 -86 94  I J PED S  Vo l. 7,  No 1,  Mar c h  2 016   : 2 2 5  –  23 23 4 [4]     M .  Odavic, V.  Biagini ,  P .  Zan c hett a, M .  S u m n er, and M .  Deg a no, “ O nes a m p le- period-ah ead  predic tive cu rre nt   control fo r high- performance  ac tive shunt power  filters”,  IET Trans. Power Electron. , vo l. 4 ,  no . 4, pp . 414–423,  Apr. 2011.  [5]     M. S.  Ha ma d,  M . I.  Ma soud,  a n d B. W.  Wi ll i a ms, “Me d i u m-voltage 12-pulse con v erter :  Output v o ltag e  harmonic  compensation us ing a series APF”,  I E EE Trans. I nd. Electron. , vo l. 61 , no . 1 ,  pp . 4 3–52, Jan .  2014   [6]     Y. Tang , P.C. Loh, P. Wang,  F.H. Choo, F. Gao ,  and F.  Blaabjer g, “Generalized  design of high p e rformance shun act ive pow er fi lt er with  output  L C L fi lter ,   IEEE Trans. I nd. Electron. , vo l. 59, no . 3 ,  pp . 1443–  14 52, Mar .  2013 [7]     A.D. le Roux H. du, T. Mouton, and   H.  Aka g i, “ D igit al  cont rol of  an  integr ated  seri es ac tiv e fi lter  and  diod e   rect ifier  with  vol tage regulation”,  IEEE Trans. In d. App l . , vo l. 39, no. 6, pp.  1814– 1820, Nov./Dec. 2003.    [8]     D. Li, Q. Chen, Z. Jia, and J. Ke , “A novel active power filter  with f undamental magnetic  flux compensation”,  IEEE Tr ans. Po wer Del., vol. 19 , no . 2 ,  pp . 799– 805, Apr. 2004.    [9]     A.D. le Roux,  H. du, T. Mouto n , and H .  Akagi, “DFT-based repetitive  contro of a series activ e filter  integr ated  with a 12-pulse  diode r ectifier”,  IEEE Tr ans. Po we r Electron., v o l. 24 , no 6 ,  pp 1515–1521, Jun. 2009.    [1 0]     Luo, C. Tang , an d Z. K. Shuai, “A novel three-ph ase h y brid  act i ve power filter wit h  a se ries resonance cir c uit tun e at  the fundamental fr equen c y I EEE Trans. Ind.  Electron. , vol. 5 6 , no . 7 ,  pp . 243 1–2440, Jul. 200 9.    [1 1]     H. Akagi and R .  Kondo, “A tran sforme rless h y br id activ e f ilter u s ing a  th ree-lev e l pulsewidth modulation  (PWM)  converter for a  mediumvoltage  motor drive”,  I EEE T r ans. Power Elec tron. , v o l. 25, no. 6 ,  pp. 1365–1374, Jun.  2010.   [1 2]     H. Akagi and K. Is ozaki, “ A  h y b r id act ive fil t er f o r a three-ph as e 12-puls e  diode r ect ifier us ed as  t h e front end of a  medium-voltage motor  drive”,  IE EE T r ans. Pow e r Ele c tron. , vol.  27, no . 1 ,  pp . 69 –77, Jan .  2012 [1 3]     V. Verm a, B .  Si ngh, A. Ch a ndra, and K .  Al-Had dad, “Power con d itioner   for v a ri able-fr equen c y  d r ives in offshore  oil f i elds”,  I E EE Trans. Ind.  Appl. , vol. 46, no. 2,  pp. 731–739 , M a r./Apr . 2010     [1 4]     Wu,   High-Power Converters an d AC Drives . Ho boken, NJ, USA: Wiley ,  Mar .  20 06.  [1 5]     M.S. Ham a d,  M.I. Masoud,   B.W. Willi am s, and S. Finney, “Mediu m  volt a ge 12-pulse converter : Ac si de  compensation using a shunt activ power filter in  a novel front  en d transformer co nfiguration”,  IET Tran s.  P o we r   Electron. , vol. 5 ,  no. 8, pp. 1315– 1323, Sep .  2012 .        Evaluation Warning : The document was created with Spire.PDF for Python.