Articles

Access the latest knowledge in applied science, electrical engineering, computer science and information technology, education, and health.

Filter Icon

Filters article

Years

FAQ Arrow
0
0

Source Title

FAQ Arrow

Authors

FAQ Arrow

31,456 Article Results

Finite frequency H∞ control for wind turbine systems in T-S form

10.11591/ijpeds.v11.i3.pp1313-1322
Salma Aboulem , Abderrahim EL-Amrani , Ismail Boumhidi
In this work, we study H∞ control wind turbine fuzzy model for finite frequency(FF) interval. Less conservative results are obtained by using Finsler’s lemma technique, generalized Kalman Yakubovich Popov (gKYP), linear matrix inequality (LMI) approach and added several separate parameters, these conditions are given in terms of LMI which can be efficiently solved numerically for the problem that such fuzzy systems are admissible with H∞ disturbance attenuation level. The FF H∞ performance approach allows the state feedback command in a specific interval, the simulation example is given to validate our results.
Volume: 11
Issue: 3
Page: 1313-1322
Publish at: 2020-09-01

Field oriented control based on a 24-sector vector space decomposition for dual three-phase PMSM applied on electric ship propulsion

10.11591/ijpeds.v11.i3.pp1175-1187
Mhammed Hasoun , Aziz El Afia , Mohamed Khafallah , Karim Benkirane
A Field Oriented Control (FOC) strategy based on a 24-Sector Vector  Space Decomposition (24SVSD) technique used to control a Dual Three-Phase Permanent Magnet Synchronous Motor (DTP-PMSM) applied on electric ship propulsion prototype is presented in this paper. This machine is supplied by Dual Three-Phase Voltage Source Inverter (DTP-VSI). This study carried out on these multiphase machines has revealed that the large zero sequence harmonic current components on (z1, z2) subspace, constitutes major drawbacks; despite their advantages. The machine’s dynamic model is accomplished in three two-dimensional and orthogonal subspaces. In order to reduce more extra stator harmonic currents that produces losses, the current work is also concering of to consider the three different approaches for the sake of boosting the machine’s efficiency. Thus, the principle selection of the reference voltage vector and the time calculation method are presented in details. The proposed strategy effectiveness is validated by simulation results.
Volume: 11
Issue: 3
Page: 1175-1187
Publish at: 2020-09-01

Optimal design of a single-phase APF based on PQ theory

10.11591/ijpeds.v11.i3.pp1360-1367
Dur Muhammad Soomro , Sager K. Alswed , Mohd Noor Abdullah , Nur Hanis Mohammad Radzi , Mazhar Hussain Baloch
The instantaneous active and reactive power (PQ) theory is one of the most widely used control theory for shunt active power filter (SAPF), which can be implemented in single-phase and three-phase systems. However, the SAPF with PQ theory still had ability to improve to become more efficient. This paper presents the optimal design of a single-phase SAPF in terms of reducing the current harmonic distortion and power loss in voltage source inverter (VSI) controlled with the semiconductor switching devices IGBT, MOSFET and Hybrid (combination of IGBT and MOSFET). In order to reduce the switching frequency and power loss of VSI, instead of using single-band hysteresis current controller (HCC), double-band HCC (DHCC) and triple-band HCC (THCC) is used in the SAPF. The designed SAPF is tested with different non-linear loads to verify the results by using MATLAB Simulink.
Volume: 11
Issue: 3
Page: 1360-1367
Publish at: 2020-09-01

Application of inductive coupling for wireless power transfer

10.11591/ijpeds.v11.i3.pp1109-1116
Ibrahim Alhamrouni , M. Iskandar , Mohamed Salem , Lilik J. Awalin , Awang Jusoh , Tole Sutikno
Considering the massive development that took place in the past two decades, wireless power transfer has yet to show the applicability to be used due to several factors. This work focuses on determining the main parameters like, mutual inductance, and coupling coefficient for a pair of helical coils for wireless power transfer applications. These parameters are important in designing and analyzing a wireless power transfer system based on the phenomenon of inductive/ resonant inductive coupling. Here presents a simple approach based on fundamental laws of physics for determining the coupled coil parameters for single layered helical coils. The results conducted by computer simulation which is MATLAB. Furthermore, this analysis is used to study the effect of change in coil diameter, mutual inductance coefficient and change in distance between coils on parameters like self and mutual inductance of coupled coils which is of great importance in Wireless Power Transfer applications. The research yielded promising results to show that wireless power transfer has huge possibility to solve many existing industrial problems.
Volume: 11
Issue: 3
Page: 1109-1116
Publish at: 2020-09-01

Parameters observation of restoration capacity of industrial lead acid battery using high current pulses

10.11591/ijpeds.v11.i3.pp1596-1602
N. S. M. Ibrahim , Asmarashid Ponniran , R. A. Rahman , M. P. Martin , A. Yassin , A. Eahambram , M. H. Aziz
Batteries play an essential role on most of the electrical equipment and electrical engineering tools. However, one of the drawbacks of lead acid batteries is PbSO4 accumulates on the battery plates, which significantly cause deterioration. Therefore, this study discusses the discharge capacity performance evaluation of the industrial lead acid battery. The selective method to improve the discharge capacity is using high current pulses method. This method is performed to restore the capacity of lead acid batteries that use a maximum direct current (DC) of up to 500 A produces instantaneous heat from 27°C to 48°C to dissolve the PbSO4 on the plates. This study uses an 840 Ah, 36 V flooded lead acid batteries for a forklift for the evaluation test. Besides, this paper explores the behavior of critical formation parameters, such as the discharge capacity of the cells. From the experimental results, it can be concluded that the discharge capacity of the flooded lead acid battery can be increase by using high current pulses method. The comparative findings for the overall percentage of discharge capacity of the batteries improved from 68% to 99% after the restoration capacity.
Volume: 11
Issue: 3
Page: 1596-1602
Publish at: 2020-09-01

Voltage regulation and power loss reduction by integration of SVC in distribution networks via PSSE

10.11591/ijpeds.v11.i3.pp1579-1587
Ba-swaimi Saleh , Lee Jun Yin , Renuga Verayiah
Voltage stability is necessary in order to maintain the health of the grid system. In recent years, the load demand is increasing from time-to-time which compromised the stability of the system. On that purpose, several methods on enhancing the voltage stability of the system was introduced such as the transformer tap and FACTS devices. In a general overview, this study is to propose a several power compensation techniques on the base case of an IEEE-33 bus whereby power flow analysis using Netwon- Raphson in PSS/E software is performed. Afterwards, distributed generation (DG) and Static VAR Compensator (SVC) will be implemented within the distribution network to compensate the voltage instability losses based on the weakest index from the bus system. From both the cases which is proposed earlier, a comparison study is conducted on the performance on both DG and SVC within the proposed network.
Volume: 11
Issue: 3
Page: 1579-1587
Publish at: 2020-09-01

Comparative analysis of sokal’s equations versus load-pull implementation of class E low-pass network

10.11591/ijeecs.v19.i3.pp1348-1357
Boodhoo Kirish , Farid Zubir , Mohamad Kamal A. Rahim , Shaharil Mohd Shah
In this paper, class E power amplifiers (PA) aimed at frequency bandwidth of 3.4 GHz to 3.6 GHz (LTE 42) and 3.6 GHz to 3.8 GHz (LTE 43) respectively are designed with objective of attaining high efficiency. The viability of Sokal’s equations for present communication systems aimed at GHz are analyzed for high efficiency using HEMT (high-electron-mobility transistor) on Nitronex NPTB00004 as opposed to the Bipolar Junction Transistor used by Sokal in 1975. Load-pull configuration techniques aimed at the drain is implemented at the output matching network (OMN) and benchmarked against Sokal’s equation. At the OMN, to suppress harmonics, band-pass filters are employed for the LTE 42 and 43 respectively. Sokal’s equation shows that the drain must be conjugately matched before his equations are applied at the OMN. The efficiency at 3.4 GHz obtained for Sokal’s circuit is at 67 % and gain of 9.3 dB. More than 65% efficiency is obtained from load-pull network at 3.4 GHz to 3.76 GHz before filter implementation while showing gain above 7.8 dB. After filter addition at OMN, the efficiency is above 65% and gain above 8 dB for dual - band having bandwidth of 3.4389 GHz - 3.542GHz and 3.6569GHz - 3.8GHz.
Volume: 19
Issue: 3
Page: 1348-1357
Publish at: 2020-09-01

Evidential reasoning based decision system to select health care location

10.11591/ijaas.v9.i3.pp201-210
Md. Mahashin Mia , Atiqur Rahman , Mohammad Shahadat Hossain
The general public’s demand of Bangladesh for safe health is rising promptly with the improvement of the living standard. However, the allocation of limited and unbalanced medical resources is deteriorating the assurance of safe health of the people. Therefore, the new hospital construction with rational allocation of resources is imminent and significant. The site selection for establishing a hospital is one of the crucial policy-related decisions taken by planners and policy makers. The process of hospital site selection is inherently complicated because of this involves many factors to be measured and evaluated. These factors are expressed both in objective and subjective ways where as a hierarchical relationship exists among the factors. In addition, it is difficult to measure qualitative factors in a quantitative way, resulting incompleteness in data and hence, uncertainty. Besides it is essential to address the subject of uncertainty by using apt methodology; otherwise, the decision to choose a suitable site will become inapt. Therefore, this paper demonstrates the application of a novel method named belief rule-based inference methodology-RIMER base intelligent decision system(IDS), which is capable of addressing suitable site for hospital by taking account of large number of criteria, where there exist factors of both subjective and objective nature.
Volume: 9
Issue: 3
Page: 201-210
Publish at: 2020-09-01

Potency of PR controller for multiple harmonic compensation for a single-phase grid connected system

10.11591/ijpeds.v11.i3.pp1491-1498
D Sattianadan , Soumen Gorai , G. R. Prudhvi Kumar , S. Vidyasagar , V. Shanmugasundaram
Harmonics and grid synchronization are one of the major problems faced when dealing with a single-phase system. The development of technology in the PV system makes the consumer to use it in a wide range. The power transferred from PV to grid needs DC to AC conversion process which is done by static devices operating with the higher frequencies that causes the harmonics in the grid connected system. The main aim of the paper is to implement grid synchronization and reduce total harmonic distortion in a single-phase grid connected system. The design of LCL filter is addressed in this paper which depends on current ripple, filter size and switching ripple attenuation.  In order to account the harmonic content, the FFT analysis is made both in analysis and Matlab Simulink. The Proportional Resonant (PR) controller is developed and work along with LCL filter for reducing the harmonic content. The stability of the system with PR is analyzed using root locus and bode plots and results are compared with PI controls. The result shows that PR controller performs better compared to the PI controller for reducing the harmonic content present in the single-phase system and for improving the system stability.
Volume: 11
Issue: 3
Page: 1491-1498
Publish at: 2020-09-01

Optimization of SHEPWM cascaded multilevel inverter switching patterns

10.11591/ijpeds.v11.i3.pp1570-1578
Ayong Hiendro , Ismail Yusuf , Junaidi Junaidi , Trias Pontia Wigyarianto , Yohannes M Simanjuntak
Selective harmonic elimination (SHE) is an efficient method to eliminate low-order selected harmonics. However, due to nonlinearity in the problems, many optimization techniques give unsatisfied performances in finding optimum switching angles for the SHE. This paper proposes a modified moth-flame optimization algorithm to eliminate selective harmonics in cascaded multilevel inverters. The optimization algorithm is employed to find sets of optimum switching angles for cascaded 5-level, 7-level, and 9-level inverters. The results have shown that modified moth-flame optimization is beneficial in finding optimum switching angles. It performs better than moth-flame optimization (MFO) and differential evolution (DE) algorithms. The optimum switching angles are applied to generate switching pulses for a cascaded 9-level inverter to demonstrate the algorithm’s accuracy. As a result, the low-order harmonics are entirely removed from the ac output voltage of the inverter.
Volume: 11
Issue: 3
Page: 1570-1578
Publish at: 2020-09-01

Nonlinear control of GTI for stabilizing future smart grids

10.11591/ijpeds.v11.i3.pp1268-1277
Salam Ibrahim Khather
The most important components of the distributed generation frameworks is the GTIs which is an interface amidst the utility and the source of energy. The recent years have seen an increased interest in the design and usage of GTIs due to its smaller weight and size, low cost and higher efficiency. But the problem of leakage currents in the transformerless inverter that is dependant on its topology and control scheme needs to be looked into carefully. Also, the high performance of the GTI requires a stringent control and various control systems are being developed and applied to the GTIs. This paper reviews the various topologies that are classified based on the attributes of the leakage current and the method of decoupling. Further it reviews and compares the different control techniques applied to the GTIs with respect to the frame of reference, controller, modulation technique and the control parameters considered.
Volume: 11
Issue: 3
Page: 1268-1277
Publish at: 2020-09-01

THD performance of single phase five level inverter using proportional resonant and harmonic compensators current controller

10.11591/ijpeds.v11.i3.pp1423-1429
Abdullahi Mohamed , Suriana Salimin
This paper observe the total harmonic distortion (THD) performance of single phase five level inverter using proportional resonant (PR) and harmonic compensators current controller. The THD when adding PR current controller was 1.6% at first. After more functions were added to the PR current controller to reduce the THD at the 3rd, 5th and 7th harmonic orders, the THD of the 3rd harmonic order was reduced from 0.45% to 0.1% while the 5th and 7th harmonic orders were reduced from 0.6% and 0.43% to 0.25% and 0.4% respectively. The development and simulation is performed using Matlab/Simulink. The simulation result is performed by using Fast Fourier Transform analysis (FFT) for the harmonics captured.
Volume: 11
Issue: 3
Page: 1423-1429
Publish at: 2020-09-01

High-speed video observations on fork lightning events in Malaysia

10.11591/ijeecs.v19.i3.pp1620-1625
Nor Asrina Binti Ramlee , N. A. Ahmad , Z. A. Baharudin , A. R. Mohamed
Malaysia is one of the countries with the highest lightning strikes incidence in the world. Yet, Malaysians are still taking a proper lightning protection indifferent manner. This might be due to lack of knowledge on lightning characteristics in Malaysia. Therefore, this study presents an unusual lightning phenomenon with multiple grounding points that might cause a disastrous event, called fork lightning. Between November and December 2018, there were three different patterns of fork lightning mechanism successfully recorded by using high speed camera with 2800 frame per second. Temporal analysis of the lightning progress had been done on the samples based only on the camera records which then played back by using Wondershare Filmora video editor. These three samples of fork lightning images were acquired among 37 lightning events recorded in this study. The first sample of fork lightning fully established the forked branch 0.35 ms before the return stroke occurred. On the contrary, second fork lightning established its forked branch 0.35 ms after the return stroke. Both forked branches for third sample simultaneously fully established with the return stroke event. Obviously, these events had striking the ground in up to ten milliseconds of time duration. Thus, there is always a possibility that they might cause serious damage and should not be neglected in designing a lightning protection system.
Volume: 19
Issue: 3
Page: 1620-1625
Publish at: 2020-09-01

Comparison of CNNs and SVM for voice control wheelchair

10.11591/ijai.v9.i3.pp387-393
Mohammad Shahrul Izham Sharifuddin , Sharifalillah Nordin , Azliza Mohd Ali
In this paper, we develop an intelligent wheelchair using CNNs and SVM voice recognition methods. The data is collected from Google and some of them are self-recorded. There are four types of data to be recognized which are go, left, right, and stop. Voice data are extracted using MFCC feature extraction technique. CNNs and SVM are then used to classify and recognize the voice data. The motor driver is embedded in Raspberry PI 3B+  to control the movement of the wheelchair prototype. CNNs produced higher accuracy i.e. 95.30% compared to SVM which is only 72.39%. On the other hand, SVM only took 8.21 seconds while CNNs took 250.03 seconds to execute. Therefore, CNNs produce better result because noise are filtered in the feature extraction layer before classified in the classification layer. However, CNNs took longer time due to the complexity of the networks and the less complexity implementation in SVM give shorter processing time.
Volume: 9
Issue: 3
Page: 387-393
Publish at: 2020-09-01

Net energy metering scheme based on time of use pricing for residents in Malaysia

10.11591/ijeecs.v19.i3.pp1140-1146
Abdul Hafiz Bin Razali
The current Malaysia’s net energy metering (NEM) scheme has been updated in 2019 that credits excess generation into the next billing month at retail rate compare to at displaced cost. The new NEM may attract more installation of solar photovoltaic (PV) system among residential customers. However, it is discovered that customers with low monthly electricity consumptions are still not benefited since their electricity cost is lower than the PV generation cost. Implementing time-of-use (TOU) pricing on NEM scheme may overcome the problem as it based on hourly energy usage. This paper compares the annualized energy cost of residential PV system under different TOU prices and NEM scheme. The results show that an optimized TOU prices as suggested in this paper may give financial benefits to all residential customers with PV system, including the one with low monthly consumption.
Volume: 19
Issue: 3
Page: 1140-1146
Publish at: 2020-09-01
Show 1187 of 2098

Discover Our Library

Embark on a journey through our expansive collection of articles and let curiosity lead your path to innovation.

Explore Now
Library 3D Ilustration