Articles

Access the latest knowledge in applied science, electrical engineering, computer science and information technology, education, and health.

Filter Icon

Filters article

Years

FAQ Arrow
0
0

Source Title

FAQ Arrow

Authors

FAQ Arrow

29,082 Article Results

Internal On-line Partial Discharge Analysis of 68.75 MVA Generator Stator Winding Insulation

10.11591/ijece.v6i5.pp2088-2095
Waluyo Waluyo , Siti Saodah , Eltha Hidayatullah
Partial discharge is a phenomenon of electron ionization occurs due to concentrated electric field in a different edge plane. This phenomenon will be investigated by an electric field measurement in a measuring point. The internal partial discharge will give the insulation damage effect on a generator stator winding due to void existence. This manuscript presents the measurement results of the on-line internal partial discharge on the stator winding insulation of 68.75 MVA generator. It used the resistant temperature detector method and CM2000TM. The results were classified into three conditions based on the voids in the generator stator insulation, the internal delamination and the surface discharge.
Volume: 6
Issue: 5
Page: 2088-2095
Publish at: 2016-10-01

Image Segmentation Based on Doubly Truncated Generalized Laplace Mixture Model and K Means Clustering

10.11591/ijece.v6i5.pp2188-2196
T Jyothirmayi , K Srinivasa Rao , P Srinivasa Rao , Ch Satyanarayana
The present paper aims at performance evaluation of Doubly Truncated Generalized Laplace Mixture Model and K-Means clustering (DTGLMM-K) for image analysis concerned to various practical applications like security, surveillance, medical diagnostics and other areas. Among the many algorithms designed and developed for image segmentation the dominance of Gaussian Mixture Model (GMM) has been predominant which has the major drawback of suiting to a particular kind of data. Therefore the present work aims at development of DTGLMM-K algorithm which can be suitable for wide variety of applications and data. Performance evaluation of the developed algorithm has been donethrough various measures like Probabilistic Rand index (PRI), Global Consistency Error (GCE) and Variation of Information (VOI). During the current work case studies forvarious different images having pixel intensities has been carried out and the obtained results indicate the superiority of the developed algorithm for improved image segmentation.
Volume: 6
Issue: 5
Page: 2188-2196
Publish at: 2016-10-01

A Secured Cloud Data Storage with Access Privileges

10.11591/ijece.v6i5.pp2338-2344
Naresh Vurukonda , B. Thirumala Rao , B. Tirapathi Reddy
In proposed framework client source information reinforcements off-site to outsider distributed storage benefits to decrease information administration costs. In any case, client must get protection ensure for the outsourced information, which is currently safeguarded by outsiders. To accomplish such security objectives, FADE is based upon an arrangement of cryptographic key operations that are self-kept up by a majority of key supervisors that are free of outsider mists. In unmistakable, FADE goes about as an overlay framework that works flawlessly on today's distributed storage administrations. Actualize a proof-of-idea model of FADE on Amazon S3, one of today's distributed storage administrations. My work oversee, esteem included security highlights acclimatize were today's distributed storage administration. our research work proceeds in ensuring the file access control and assured deletion in multi cloud environment and reducing the meta data management, there by the cloud storage become more attractive and many users will adopt the cloud space in order to diminish the data storage cost.
Volume: 6
Issue: 5
Page: 2338-2344
Publish at: 2016-10-01

Optimal Placement of TCSC Based on Sensitivity Analysis for Congestion Management

10.11591/ijece.v6i5.pp2041-2047
Naga Raja Kumari.CH , K. Chendra Sekhar
In a deregulated electricity market whenever congestion management problem occurs, the network collapse because of voltage instability. In this paper total real and reactive power loss deviation based sensitivity indexes (PLDS and QLDS) with rank co-relation concept, has been proposed for the optimal location and operating range of TCSC device. With this placement  the power flow in over loaded overhead lines has been reduced and that results in an increased loadability of the power system and also improves the voltage stability and security and also solves the congestion management problem. So ultimately, a more energy efficient transmission system is possible. The case studies were conducted on IEEE 14 bus test system. The ensue corroborate the intended approach for social welfare maximization inreal time.
Volume: 6
Issue: 5
Page: 2041-2047
Publish at: 2016-10-01

A Modulation Scheme for Floating Source Multilevel Inverter Topology with Increased Number of Output Levels

10.11591/ijece.v6i5.pp1985-1993
Hussain M. Bassi
This paper presented and studied a new switching scheme for floating source multilevel inverters to produce more levels with the same number of switching devices. In the proposed scheme, the function of the dc sources, except the inner one, is to build up square wave or blocks that is close in the shape to the desired sinusoidal wave. The job of the inner switching devices is to increase the number of the levels to produce smother sinusoidal wave in the inverter output. This job can be done by adding or subtracting the value of the inner dc source to/from the blocks. The topology used in this paper is based on the conventional floating source multi-level inverter using two legs. This topology and modulation technique show substantial reduction in the total harmonics distortion when the modulation technique is the hybrid method. The performance of the proposed switching scheme in generating more levels has been evaluated by PSCAD/EMTDC simulation.
Volume: 6
Issue: 5
Page: 1985-1993
Publish at: 2016-10-01

A Novel Approach to PID Controller Design for Improvement of Transient Stability and Voltage Regulation of Nonlinear Power System

10.11591/ijece.v6i5.pp2225-2238
Rekha Chaudhary , Arun Kumar Singh , Saligram Agrawal
In this paper, a novel design method for determining the optimal PID controller parameters for non-linear power system using the particle swarm optimization (PSO) algorithm is presented. The direct feedback linearization (DFL) technique is used to linearize the nonlinear system for computing the PID (DFL-PID) controller parameters. By taking an example of single machine infinite bus (SMIB) power system it has been shown that PSO based PID controller stabilizes the system and restores the pre-fault system performance after fault is cleared and line is restored. The performance of this controlled system is compared with the performance of DFL-state feedback controlled power system. It has been shown that the performance of DFL-PID controlled system is superior compared to DFL-state feedback controlled system. For simulation MATLAB 7 software is used. 
Volume: 6
Issue: 5
Page: 2225-2238
Publish at: 2016-10-01

Stochastic Approach to a Rain Attenuation Time Series Synthesizer for Heavy Rain Regions

10.11591/ijece.v6i5.pp2379-2386
Masoud Mohebbi Nia , Jafri Din , Hong Yin Lam , Athanasios D. Panagopoulos
In this work, a new rain attenuation time series synthesizer based on the stochastic approach is presented. The model combines a well-known interest-rate prediction model in finance namely the Cox-Ingersoll-Ross (CIR) model, and a stochastic differential equation approach to generate a long-term gamma distributed rain attenuation time series, particularly appropriate for heavy rain regions. The model parameters were derived from maximum-likelihood estimation (MLE) and Ordinary Least Square (OLS) methods. The predicted statistics from the CIR model with the OLS method are in good agreement with the measurement data collected in equatorial Malaysia while the MLE method overestimated the result. The proposed stochastic model could provide radio engineers an alternative solution for the design of propagation impairment mitigation techniques (PIMTs) to improve the Quality of Service (QoS) of wireless communication systems such as 5G propagation channel, in particular in heavy rain regions.
Volume: 6
Issue: 5
Page: 2379-2386
Publish at: 2016-10-01

Bangladesh Perspective: Vehicle Speed Proposition System using Localized Wireless Identification

10.11591/ijece.v6i5.pp2134-2139
Md. Mamunoor Islam , Mehdi Hasan Chowdhury
Even in the era of advanced engineering, road accident has been a regular phenomenon causing death of many people in Bangladesh due to over speeding action of reckless drivers. There are several key places (such as schools, colleges, hospitals, highways and constructional areas etc.) where the speed of the vehicle should be lessened to avoid accidents. The roads and highways authority may place the speed limiter signboards in these areas to avoid these accidents, but these are frequently overlooked by the drivers. So this paper demonstrates a wireless forewarning system which will aid to control the speed of the vehicles at speed restricted areas. The whole system is established on the basis of radio frequency (RF) communication. There are two parts of this system named as transmitting unit and receiving unit. Each RF transmitter positioned on the roadside will be transmitting the code signal continuously. Whenever the vehicle enters the range of transmission, the RF receiver which is attached in the vehicle, will receive the signal and will display the information in a LCD monitor by notifying the driver to reduce the speed while going through that area.
Volume: 6
Issue: 5
Page: 2134-2139
Publish at: 2016-10-01

Design of a Front-End for Satellite Receiver

10.11591/ijece.v6i5.pp2282-2290
Tran Van Hoi , Ngo Thi Lanh , Nguyen Xuan Truong , Nguyen Huu Duc , Bach Gia Duong
This paper focuses on the design and implementation of a front-end for a Vinasat satellite receiver with auto-searching mechanism and auto-tracking satellite. The front-end consists of a C-band low-noise block down-converter and a L-band receiver. The receiver is designed to meet the requirements about wide-band, high sensitivity, large dynamic range, low noise figure. To reduce noise figure and increase bandwidth, the C-band low-noise amplifier is designed using T-type of matching network with negative feedback and the L-band LNA is designed using cascoded techniques. The local oscillator uses a voltage controlled oscillator combine phase locked loop to reduce the phase noise and select channels. The front-end has successfully been designed and fabricated with parameters: Input frequency is C-band; sensitivity is greater than -130 dBm for C-band receiver and is greater than -110dBm for L-band receiver; output signals are AM/FM demodulation, I/Q demodulation, baseband signals.
Volume: 6
Issue: 5
Page: 2282-2290
Publish at: 2016-10-01

A Normative Process Model for ICT Business Continuity Plan for Disaster Event in Small, Medium and Large Enterprises

10.11591/ijece.v6i5.pp2425-2431
Fadeel Sambo , Felix Olu Bankole
Small, Medium and Large Enterprises (SMLs) are exposed to the risks of business interruption as they expand and become more dependent on Information Communication Technology (ICT) infrastructure. The current study seeks to determine why organization that have Business Continuity Plan (BCP) in place and implement regular testing of their plan still experience prolong downtime during a disaster event resulting in Service Level Agreement (SLA) not being met or major financial loss. By employing a descriptive analytics approach through a qualitative case study, the research propose a normative process model for comprehensive procedures of BCP for business leaders, ICT service managers, IS executives, data science researchers, risk managers, entrepreneur and policy makers on how to adopt strategies on effective disaster risk reduction and management in organizations. The current study offer both theoretical and practical implications for BCP in small, medium and large enterprises.
Volume: 6
Issue: 5
Page: 2425-2431
Publish at: 2016-10-01

Design of MPC for Superheated Steam Temperature Control in a Coal-fired Thermal Power Plant

10.11591/ijeecs.v4.i1.pp73-82
A. Yasmine Begum , G. V. Marutheeswar
A superheater is a vital part of the steam generation process in the boiler-turbine system. Reliable control of temperature in the superheated steam temperature system is essential to guarantee efficiency and high load-following capability in the operation of coal-fired Thermal power plant. The PI and PID controllers are extensively used in cascade control of secondary superheated steam temperature process.The design and implementation of a Model Predictive Control (MPC) strategy for the superheated steam temperature regulation in a thermal power plant is presented. A FOPTD model  is derived from  the dynamic model of the superheater. This model is required by the MPC algorithm to calculate the future control inputs. A new MPC controller is designed and its performance is tested through simulation studies. Compared with the superheater steam temperature control using a conventional PID controller, the steam temperature controlled by the MPC controller is found to be more stable. The stable steam temperature leads to energy saving and efficient plant operation, as verified by the simulation results. 
Volume: 4
Issue: 1
Page: 73-82
Publish at: 2016-10-01

Spatio-Temporal Typology of Land and Forest Fire in Sumatra

10.11591/ijeecs.v4.i1.pp83-90
Israr Albar , I. Nengah Surati Jaya , Bambang Hero Saharjo , Budi Kuncahyo
The characteristic of land and forest fires occurred in Indonesia are varied widely, following the variation of time within a year and geographic location. This paper describes how the spatio-temporal of forest and land fire typology was developed. The main objective of this study was to develop a spatio-temporal typology of forest and land fire by considering several key indicators that directly related to the density of active fire occurrence, such as percentage of forest area (x1), population density (x2), ratio of forest area to population (x3), ratio of plantation area to population (x4), ratio of agriculture area to population (x5), GRDP (x6), population growth (x7), deforestation growth (x8), plantation growth (x9) and dry agriculture growth (x10) as well as  MODIS-based fire hotspot. The typology analysis was performed using clustering techniques with Euclidean distance dissimilarity measure, where the grouping process was drawn with single linkage method. The temporal analysis showed that the highest occurrence of the fire hotspot was mainly found in the third quarter. It was found that the forest and land fire typology could be developed into three classes using variables x6 and x7 with overall accuracy of 78.15% or x1-x6-x7 with overall accuracy of 78.8%.  No accuracy improvement was obtained when the typology was developed using five variables x1-x3-x4-x6-x7.
Volume: 4
Issue: 1
Page: 83-90
Publish at: 2016-10-01

An Improved Criterion for Induced Stability of Fixed-Point Digital Filters with Saturation Arithmetic

10.11591/ijeecs.v4.i1.pp65-72
Priyanka Kokil , Xavier Arockiaraj S
This paper establishes a criterion for the induced  stability of fixed-point state-space digital filters with saturation nonlinearities and external interference. The criterion is established in a linear matrix inequality (LMI) setting, and therefore, computationally tractable. The criterion turns out to be an improvement over a previously reported criterion. A comparison of the presented criterion with existing criterion is made. Numerical examples are given to demonstrate the usefulness of the proposed approach.
Volume: 4
Issue: 1
Page: 65-72
Publish at: 2016-10-01

Performance Analysis of SMES Integrated with Offshore Wind Farms to Power Systems through MT-HVDC

10.11591/ijeecs.v4.i1.pp1-9
Mohammed A. Badr , Ahmed M. Atallah , Mona A. Bayoumi
With the increase in the development of offshore wind farm (OWF) around the world, this paper describes OWF consisting of permanent magnet synchronous generator (PMSG) wind turbines connected to Active network (AC grid) and Passive network (loads) through Multi Terminal High voltage direct current(MT-HVDC) transmission system. This paper discusses the effect of using a Superconducting Magnetic Energy Storage (SMES) unit in a hybrid power system that contains OWF. In this paper, we have aggregated 300 wind turbines of 1.5 MW PMSG using an aggregation technique (multi full aggregated model using equivalent wind speed (MFAM_EWS)). Furthermore, we have used a detector to detect any tripping of any wind turbine and substitute the shortage of power due to this loss of wind turbines immediately through SMES. The Active network in this paper should have a minimum of 150 MW power to be supplied by controlling the SMES unit (absorbing or providing power according to the system requirement). Simulation has been carried out by MATLAB/Simulink program to test the effectiveness of the SMES unit during tripping some of the wind turbines, fluctuation in wind speeds, load change and voltage dips. 
Volume: 4
Issue: 1
Page: 1-9
Publish at: 2016-10-01

A New P System Based Genetic Algorithm

10.11591/ijeecs.v4.i1.pp165-168
Caiping Hou , Xiyu Liu
For the “early convergence” or the “genetic drift” of the genetic algorithm, this paper proposes a new genetic algorithm based on P system. Based on the parallel mechanism of P system in membrane computing, we put forward the new P system based genetic algorithm (PBGA). So that we can improve the performance of GA.
Volume: 4
Issue: 1
Page: 165-168
Publish at: 2016-10-01
Show 1565 of 1939

Discover Our Library

Embark on a journey through our expansive collection of articles and let curiosity lead your path to innovation.

Explore Now
Library 3D Ilustration