Articles

Access the latest knowledge in applied science, electrical engineering, computer science and information technology, education, and health.

Filter Icon

Filters article

Years

FAQ Arrow
0
0

Source Title

FAQ Arrow

Authors

FAQ Arrow

31,456 Article Results

Quality of Service based Task Scheduling Algorithms in Cloud Computing

10.11591/ijece.v7i2.pp1088-1095
Sirisha Potluri , Katta Subba Rao
In cloud computing resources are considered as services hence utilization of the resources in an efficient way is done by using task scheduling and load balancing. Quality of service is an important factor to measure the trustiness of the cloud. Using quality of service in task scheduling will address the problems of security in cloud computing. This paper studied quality of service based task scheduling algorithms and the parameters used for scheduling. By comparing the results the efficiency of the algorithm is measured and limitations are given. We can improve the efficiency of the quality of service based task scheduling algorithms by considering these factors arriving time of the task, time taken by the task to execute on the resource and the cost in use for  the communication.
Volume: 7
Issue: 2
Page: 1088-1095
Publish at: 2017-04-01

Credal Fusion of Classifications for Noisy and Uncertain Data

10.11591/.v7i2.pp1071-1087
Fatma Karem , Mounir Dhibi , Arnaud Martin , Med Salim Bouhlel
This paper reports on an investigation in classification technique employed to classify noised and uncertain data. However, classification is not an easy task. It is a significant challenge to discover knowledge from uncertain data. In fact, we can find many problems. More time we don't have a good or a big learning database for supervised classification. Also, when training data contains noise or missing values, classification accuracy will be affected dramatically. So to extract groups from  data is not easy to do. They are overlapped and not very separated from each other. Another problem which can be cited here is the uncertainty due to measuring devices. Consequentially classification model is not so robust and strong to classify new objects. In this work, we present a novel classification algorithm to cover these problems. We materialize our main idea by using belief function theory to do combination between classification and clustering. This theory treats very well imprecision and uncertainty linked to classification. Experimental results show that our approach has ability to significantly improve the quality of classification of generic database.
Volume: 7
Issue: 2
Page: 1071-1087
Publish at: 2017-04-01

Design of Pervasive Discovery, Service and Control for Smart Home Appliances: An Integration of Raspberry Pi, UPnP Protocols and Xbee

10.11591/.v7i2.pp1012-1022
Sabriansyah Rizqika Akbar , Maystya Tri Handono , Achmad Basuki
Pervasive technology is an important feature in smart home appliances control. With pervasive technology, the user is able to discover and control every device and each service without initialization configuration and setup. Since single-board computer often used in smart home appliances, combining pervasive technology and microcomputer/single-board computer will be important to be applied and make a possibility to create a smart home system based on the requirement of it users that will be beneficial for the smart home users and the developers. This paper proposed a design of pervasive discovery, service, and control system for smart home appliances by integrating Raspberry Pi, UPnP protocols, and Xbee that able to control an RGB LED services such as switching, dimming, change color and read a temperature sensor as an example in smart home appliances. This paper enriched the raspberry Pi GPIO function to be able to control via TCP/IP network with UPnP protocol and receive information from a temperature sensor node via Xbee communication. Service control time is measured with UPnP round trip time by subtracting HTTP response arrival with HTTP request time. GPIO processing time measured at the application level by counting a timer that starts before GPIO process and ended after GPIO successfully executed.
Volume: 7
Issue: 2
Page: 1012-1022
Publish at: 2017-04-01

5G Fixed Beam Switching on Microstrip Patch Antenna

10.11591/.v7i2.pp975-980
Low Ching Yu , Muhammad Ramlee Kamarudin
5G technology is using millimeter-wave band to improve the wireless communication system.  However, narrow transmitter and receiver beams have caused the beam coverage area to be limited. Due to propagation limitations of mm wave band, beam forming technology with multi-beam based communication system, has been focused to overcome the problem. In this letter, a fixed beam switching method is introduced. By changing the switches, four different configurations of patch array antennas are designed to investigate their performances in terms of radiation patterns, beam forming angle, gain, half-power bandwidth and impedance bandwidth at 28 GHz operating frequency for 5G application. Mircostrip antenna is preferred due to its low profile, easy in feeding and array configurations. Three different beam directions had been formed at -15°, 0°, and 15° with half-power bandwidth of range 45˚ to 50˚.
Volume: 7
Issue: 2
Page: 975-980
Publish at: 2017-04-01

Voltage Compensation In Wind Power System Using STATCOM Controlled By Soft Computing Techniques

10.11591/.v7i2.pp667-680
Bineeta Mukhopadhyay , Rajib Kumar Mandal , Girish Kumar Choudhary
When severe voltage sags occur in weak power systems associated with grid-connected wind farms employing doubly fed induction generators, voltage instability occurs which may lead to forced disconnection of wind turbine. Shunt flexible AC transmission system devices like static synchronous compensator (STATCOM) may be harnessed to provide voltage support by dynamic injection of reactive power. In this work, the STATCOM provided voltage compensation at the point of common coupling in five test cases, namely, simultaneous occurrence of step change (drop) in wind speed and dip in grid voltage, single line to ground, line to line, double line to ground faults and sudden increment in load by more than a thousand times. Three techniques were employed to control the STATCOM, namely, fuzzy logic, particle swarm optimization and a combination of both. A performance comparison was made among the three soft computing techniques used to control the STATCOM on the basis of the amount of voltage compensation offered at the point of common coupling. The simulations were done with the help of SimPowerSystems available with MATLAB / SIMULINK and the results validated that the STATCOM controlled by all the three techniques offered voltage compensation in all the cases considered.
Volume: 7
Issue: 2
Page: 667-680
Publish at: 2017-04-01

Z–Source Multilevel Inverter Based on Embedded Controller

10.11591/ijeecs.v6.i1.pp1-8
K. Vijayalakshmi , Chinnapettai Ramalingam Balamurugan
In this paper Embedded based Z-source multilevel inverter (ZSMLI) is proposed. This work implements a five level cascaded H-bridge Z-source inverter by using embedded control. Switching devices are triggered using embedded controller. In this controller coding is described by using switching table. The presence of Z-source network couples inverter main circuit to the power source that providing special features that can overcome the limitations of VSI (voltage source inverter) and CSI (current source inverter). The Z-source concept can applicable in all dc-ac, dc-dc, ac-dc and ac-ac power conversions. Simulation model of Z-source multilevel inverter based on embedded controller has been built in MATLAB/SIMULINK. The Performance parameters of Z-source MLI such as RMS (root mean square) output voltage, THD (total harmonic distortion) and DC component have been analysed for various inductance (L) and capacitance (C) value.
Volume: 6
Issue: 1
Page: 1-8
Publish at: 2017-04-01

5G Coupler Design for Intelligent Transportation System (ITS) Application

10.11591/.v7i2.pp899-904
Dyg Norkhairunnisa Abang Zaidel , Norhudah Seman , Mohd Ridhuan Mohd Sharip , Dyg Azra Awang Mat , Nur Alia Athirah Mohtadzar
Aiming to achieve 3-dB coupling, operating in fifth generation (5G) technologies, this paper introduces a new design of tight coupling coupler that will be operated in 5G technologies. Two stubs and two slots have been implemented into the 3-dB coupler design in order to achieve impedance matching between the ports and to give better coupling performances, respectively. Moreover, a study on the stubs’ and slots’ effects towards the S31 of the 3-dB coupler has also been presented in this paper. The proposed coupler is designed on Rogers RO4003C substrate. The simulation results and the analytical study on the stubs and slots implementation show that both stubs and slots affect the performance of the coupling coefficient.
Volume: 7
Issue: 2
Page: 899-904
Publish at: 2017-04-01

Identification of Thalassemia Disorder using Active Contour

10.11591/ijeecs.v6.i1.pp160-165
Nurhanis Izzati Binti Che Marzuki Izzati Binti Che Marzuki , Nasrul Humaimi bin Mahmood Humaimi bin Mahmood , Mohd Azhar bin Abdul Razak
Thalassemia was known as the red blood cell (RBC) morphology disorder. This disease mostly affects the shape of the red blood cells. Thalassemia becomes the major public health problem when one of the people becomes the carrier of the disease. It can occur within a months after birth or even before birth and results in inappropriate growth and development of babies. Sometimes the affected babies will die shortly after birth. In order to screen thalassemia, there are a few tests need to be done. Firstly by performed Complete Blood Count (CBC) and secondly continued with hemoglobin electrophoresis test. This CBC test will identify the morphology of RBC. Hence, this paper will discuss the methods on identifying the morphology of thalassemia blood cells by using active contour technique. From the result of 16 normal and abnormal blood cell images, the active countour methods able to identifyThalassemia blood cells with accuracy of 90% from the abnormal cell images.
Volume: 6
Issue: 1
Page: 160-165
Publish at: 2017-04-01

Hybrid System of Tiered Multivariate Analysis and Artificial Neural Network for Coronary Heart Disease Diagnosis

10.11591/.v7i2.pp1023-1031
Wiharto Wiharto , Hari Kusnanto , Herianto Herianto
Improved system performance diagnosis of coronary heart disease becomes an important topic in research for several decades. One improvement would be done by features selection, so only the attributes that influence is used in the diagnosis system using data mining algorithms. Unfortunately, the most feature selection is done with the assumption has provided all the necessary attributes, regardless of the stage of obtaining the attribute, and cost required. This research proposes a hybrid model system for diagnosis of coronary heart disease. System diagnosis preceded the feature selection process, using tiered multivariate analysis. The analytical method used is logistic regression. The next stage, the classification by using multi-layer perceptron neural network. Based on test results, system performance proposed value for accuracy 86.3%, sensitivity 84.80%, specificity 88.20%, positive prediction value (PPV) 90.03%, negative prediction value (NPV) 81.80%, accuracy 86,30%  and area under the curve (AUC) of 92.1%. The performance of a diagnosis using a combination attributes of risk factors,symptoms and exercise ECG. The conclusion that can be drawn is that the proposed diagnosis system capable of delivering performance in the very good category, with a number of attributes that are not a lot of checks and a relatively low cost.
Volume: 7
Issue: 2
Page: 1023-1031
Publish at: 2017-04-01

Wide Area Oscillation Damping using Utility-Scale PV Power Plants Capabilities

10.11591/.v7i2.pp681-691
Mehrdad Moradi , Pouria Maghouli
With increasing implementation of Wide Area Measurement Systems (WAMS) in power grids, application of wide area damping controllers (WADCs) to damp power system oscillations is of interest. On the other hand it is well known that rapidly increasing integration of renewable energy sources into the grid can dangerously reduce the inertia of the system and degrade the stability of power systems. This paper aimed to design a novel WADC for a utility-scale PV solar farm to damp out inter area oscillations while the main focus of the work is to eliminate the impact of communication delays of wide-area signals from the WAMS. Moreover the PV farm impact on inter area oscillation mitigation is investigated in various case studies, namely, with WADC on the active power control loop and with WADC on the reactive power control loop. The Quantum Particle Swarm Optimization (QPSO) technique is applied to normalize and optimize the parameters of WADC for inter-area oscillations damping and continuous compensation of time-varying latencies. The proposed method is prosperously applied in a 16-bus six-machine test system and various case studies are conducted to demonstrate the potential of the proposed structure.
Volume: 7
Issue: 2
Page: 681-691
Publish at: 2017-04-01

Self-Healing Properties of Silicone Rubber Against Relative Humidity and Nanofiller

10.11591/ijeecs.v6.i1.pp166-171
Izzah Hazirah Zakaria , Muhammad Taufik Kamaruddin , Yanuar Z. Arief , Mohd Hafizi Ahmad , Noor Azlinda Ahmad , Nor Asiah Muhamad , Zuraimy Adzis
A well-prepared abstract enables the reader to identify the basic content of a document quickly and accurately, to determine its relevance to their interests, and thus to decide whether to read the document in its entirety. The Abstract should be informative and completely self-explanatory, provide a clear statement of the problem, the proposed approach or solution, and point out major findings and conclusions. The Abstract should be 100 to 150 words in length. The abstract should be written in the past tense. Standard nomenclature should be used and abbreviations should be avoided. No literature should be cited. The keyword list provides the opportunity to add keywords, used by the indexing and abstracting services, in addition to those already present in the title. Judicious use of keywords may increase the ease with which interested parties can locate our article.
Volume: 6
Issue: 1
Page: 166-171
Publish at: 2017-04-01

Development of Load Control Algorithm for PV Microgrid

10.11591/.v7i2.pp619-630
Mohamad Haireen Bin Fatheli , Nur Izzati Zolkifri , Chin Kim Gan , Musa Bin Yusup Lada
The variability of solar irradiance which is caused by the weather conditions could result in the mismatch between the solar PV generation and the demand particularly in the microgrid context. This may lead to the detrimental effects of over/under voltage or over/under frequency. In this regard, this paper presents the laboratory set-up of a grid-connected PV inverter operates in islanding condition. To achieve this, a load control algorithm is proposed to provide the autonomous real time demand control that follows the PV generation to maintain generation-demand equilibrium requirement. The laboratory results show that the proposed load control algorithm can successfully address the voltage and the frequency violation in islanding condition, regardless of the variation of irradiance and power generated by the PV sources.
Volume: 7
Issue: 2
Page: 619-630
Publish at: 2017-04-01

Lyot-based Multi-wavelength Fiber Laser

10.11591/.v7i2.pp981-985
Suhairie Saleh , N. A. Cholan , A. H. Sulaiman , M. A. Mahdi
A multi-wavelength fiber laser which is based on a Lyot filter is experimentally demonstrated. A combination of four-wave mixing in a highly nonlinear fiber and Lyot filter mechanism in the laser cavity is able to generate multi-wavelength with relatively high extinction ratio (ER). At the input current of 100mA, six laser lines with ER more than 5 dB are successfully generated. The wavelength spacing for the multi-wavelength is 0.15nm, corresponding to the characteristics of the Lyot filter used.
Volume: 7
Issue: 2
Page: 981-985
Publish at: 2017-04-01

Exploring the Design Space of HEVC Inverse Transforms with Dataflow Programming

10.11591/ijeecs.v6.i1.pp104-109
Khoo Zhi Yion , Ab Al-Hadi Ab Rahman
This paper presents the design space exploration of the hardware-based inverse fixed-point integer transform for High Efficiency Video Coding (HEVC). The designs are specified at high-level using CAL dataflow language and automatically synthesized to HDL for FPGA implementation. Several parallel design alternatives are proposed with trade-off between performance and resource. The HEVC transform consists of several independent components from 4x4 to 32x32 discrete cosine transform and 4x4 discrete sine transform. This work explores the strategies to efficiently compute the transforms by applying data parallelism on the different components. Results show that an intermediate version of parallelism, whereby the 4x4 and 8x8 are merged together, and the 16x16 and 32x32 merged together gives the best trade-off between performance and resource. The results presented in this work also give an insight on how the HEVC transform can be designed efficiently in parallel for hardware implementation.
Volume: 6
Issue: 1
Page: 104-109
Publish at: 2017-04-01

Novel 9-Steps Automatic AC Voltage Regulator based on Two Step-down Transformers

10.11591/.v7i2.pp576-583
Hussain Attia
A novel design and simulation results of 9-steps automatic AC voltage regulator based on one step-down transformer is presented in this paper. Avoiding the problem of surge at the AC load during controlling jump steps is done through the proposed design. Accurate and smooth controlling function is achieved as well. Instead of the necessity of increasing the number of taps of the used multi tap transformer for wide controlling range of fluctuated AC  supply voltage, the proposed designed adopts using only two step down transformers with 10 Vrms, and 30 Vrms secondary voltages respectively. Through the controlling of the proposed design of AV voltage regulator, the resultant load voltage is equal the AC supply voltage as well as the suitable voltage step which may one of the following voltages; +40V, +30V, +20V, +10V, 0V, -10V, -20V, -30V, -40V. The electronic design is done Multisim software while the electrical circuit connection of step down transformers and relays contacts that is made by using PSIM software for power circuit design.
Volume: 7
Issue: 2
Page: 576-583
Publish at: 2017-04-01
Show 1672 of 2098

Discover Our Library

Embark on a journey through our expansive collection of articles and let curiosity lead your path to innovation.

Explore Now
Library 3D Ilustration