Articles

Access the latest knowledge in applied science, electrical engineering, computer science and information technology, education, and health.

Filter Icon

Filters article

Years

FAQ Arrow
0
0

Source Title

FAQ Arrow

Authors

FAQ Arrow

31,456 Article Results

Wide Area Oscillation Damping using Utility-Scale PV Power Plants Capabilities

10.11591/.v7i2.pp681-691
Mehrdad Moradi , Pouria Maghouli
With increasing implementation of Wide Area Measurement Systems (WAMS) in power grids, application of wide area damping controllers (WADCs) to damp power system oscillations is of interest. On the other hand it is well known that rapidly increasing integration of renewable energy sources into the grid can dangerously reduce the inertia of the system and degrade the stability of power systems. This paper aimed to design a novel WADC for a utility-scale PV solar farm to damp out inter area oscillations while the main focus of the work is to eliminate the impact of communication delays of wide-area signals from the WAMS. Moreover the PV farm impact on inter area oscillation mitigation is investigated in various case studies, namely, with WADC on the active power control loop and with WADC on the reactive power control loop. The Quantum Particle Swarm Optimization (QPSO) technique is applied to normalize and optimize the parameters of WADC for inter-area oscillations damping and continuous compensation of time-varying latencies. The proposed method is prosperously applied in a 16-bus six-machine test system and various case studies are conducted to demonstrate the potential of the proposed structure.
Volume: 7
Issue: 2
Page: 681-691
Publish at: 2017-04-01

A New Compact and Miniaturized GCPW-fed Slotted Rectangular antenna for Wideband UHF FIRD Applications

10.11591/.v7i2.pp767-774
Rachid Dakir , Jamal Zbitou , Ahmed Mouhsen , A. Tribak , M. Latrach , A. M. Sanchez
This paper presents the development of a new miniaturized and compact GCPW-fed slotted rectangular antenna structure reader for wideband UHF RFID applications. The optimized proposed antenna is suitable to operate a large frequency-band range from 0.8GHz to 1.3GHz with a bandwidth of 500MHz with a return loss less than -10dB. The antenna is based on a 1.6mm thickness FR4 epoxy substrate with a reduce dimensions compared to the simple rectangular antenna and size of proposed antenna is 47*40mm2. The new design consists of a compact rectangular patch with symmetric U-shaped slots and I-shaped include a partial ground plan and fed by 50 Grounded coplanar line. The antenna parameters have been investigated and optimized by   using   CST Microwave Studio. To validate the CST Microwave Studio results before the   antenna achievement,   we   have   conducted another study by using ADS. The   final circuit   achieved, measured and validated. Experimental results show that the proposed antenna has good radiation characteristics and operating in UHF-RFID applications.
Volume: 7
Issue: 2
Page: 767-774
Publish at: 2017-04-01

Video Monitoring Application using Wireless Sensor Node with Various External Antenna

10.11591/ijeecs.v6.i1.pp148-154
Amerrul Zabri , Mohamad Kamal A. Rahim , Farid Zubir , Norsaidah Muhamad Nadzir , Huda A. Majid
Surveillance and monitoring has become very important for security reasons these days. The use of wireless sensor node device offers a variety of platform depends on the attached sensor. When an image sensor is attached, the wireless sensor node is capable of monitoring an area wirelessly. Since wireless environment uses antenna to transmit and receive data, antenna is an important component that affects the video monitoring performance. This paper describes a surveillance system using Raspberry Pi with various external antenna. The Raspberry Pi with Pi Camera module and various types of antennas was used for testing and experimentation in line-of-sight (LOS) and non-line-of-sight (NLOS) condition. The results revealed that the Yagi Uda antenna gives the best output in terms of its signal strength and average Receive (Rx) rate.
Volume: 6
Issue: 1
Page: 148-154
Publish at: 2017-04-01

Novel 9-Steps Automatic AC Voltage Regulator based on Two Step-down Transformers

10.11591/.v7i2.pp576-583
Hussain Attia
A novel design and simulation results of 9-steps automatic AC voltage regulator based on one step-down transformer is presented in this paper. Avoiding the problem of surge at the AC load during controlling jump steps is done through the proposed design. Accurate and smooth controlling function is achieved as well. Instead of the necessity of increasing the number of taps of the used multi tap transformer for wide controlling range of fluctuated AC  supply voltage, the proposed designed adopts using only two step down transformers with 10 Vrms, and 30 Vrms secondary voltages respectively. Through the controlling of the proposed design of AV voltage regulator, the resultant load voltage is equal the AC supply voltage as well as the suitable voltage step which may one of the following voltages; +40V, +30V, +20V, +10V, 0V, -10V, -20V, -30V, -40V. The electronic design is done Multisim software while the electrical circuit connection of step down transformers and relays contacts that is made by using PSIM software for power circuit design.
Volume: 7
Issue: 2
Page: 576-583
Publish at: 2017-04-01

Improved Timing Estimation Using Iterative Normalization Technique for OFDM Systems

10.11591/.v7i2.pp905-911
Suyoto Suyoto , Iskandar Iskandar , Sugihartono Sugihartono , Adit Kurniawan
Conventional timing estimation schemes based on autocorrelation experience performance degradation in the multipath channel environment with high delay spread. To overcome this problem, we proposed an improvement of the timing estimation for the OFDM system based on statistical change of symmetrical correlator. The new method uses iterative normalization technique to the correlator output before the detection based on statistical change of symmetric correlator is applied. Thus, it increases the detection probability and achieves better performance than previously published methods in the multipath environment. Computer simulation shows that our method is very robust in the fading multipath channel
Volume: 7
Issue: 2
Page: 905-911
Publish at: 2017-04-01

Optical Humidity Sensor Based on Tapered Fiber with Multi-walled Carbon Nanotubes Slurry

10.11591/ijeecs.v6.i1.pp97-103
Habibah Mohamed , Ninik Irawati , Fauzan Ahmad , Mohd Haniff Ibrahim , Sumiaty Ambran , Mohd Azizi Abdul Rahman , Sulaiman Wadi Harun
We demonstrated performance comparison of optical humidity sensor for bare and Multi-walled carbon nanotubes (MWCNTs) slurry coated tapered optical fiber. The starting material for MWCNTs slurry is MWCNTs- acrylonitrile butadiene styrene (ABS) based fused deposition modeling (FDM) 3D printer filament. The ABS was dissolved using acetone to produce MWCNTs-acetone suspension. The MWCNTs-acetone suspension was drop-casted on the tapered fiber to produce MWCNTs slurry by evaporation process at room temperature, which resulted the MWCNTs slurry attach to the tapered fiber. The MWCNTs slurry acts as the cladding for humidity changes measurement. The experimental works showed improvement of sensitivity from 3.811 μW/% of bare tapered fiber to 5.17 μW/% for the coated tapered fiber with MWCNTs slurry when the humidity varied from 45% to 80%.
Volume: 6
Issue: 1
Page: 97-103
Publish at: 2017-04-01

Generator Assessment of Hydro Power Station Adequacy after Reconstruction from Classical to HIS SF6 Substation

10.11591/.v7i2.pp729-740
Srete Nikolovski , Goran Slipac , Emir Alibašić
Reliability analysis of substations and generator assessment of power plant stations are very important elements in a design and maintenance process. This paper presents a generator adequacy assessment of a classical “H” scheme for an open conventional substation, which is often used, and a new HIS - High Integrated Switchgear with SF6 gas isolation. Generator adequacy indices of both types of classical and HIS switchgear were compared and the results showed a high level of reliability and availability of the HIS presented substation. The input data were the annual reports of Croatian TSO-Transmission System Operator (HOPS) and statistics of operation events of Croatian National Electricity (HEP Inc.). For the HIS substation, the input reliability data were used from relevant international literature since only few of HIS substations are installed in Croatia. The generator is modelled with a three-state Markov state space model and Monte Carlo simulations were used for the generator assessment analysis. Adequacy indices LOLP and EDNS were obtained using DIgSILENT software.
Volume: 7
Issue: 2
Page: 729-740
Publish at: 2017-04-01

Optimal Siting of Distributed Generators in a Distribution Network using Artificial Immune System

10.11591/.v7i2.pp641-649
Meera P.S. , S. Hemamalini
Distributed generation (DG) sources are being installed in distribution networks worldwide due to their numerous advantages over the conventional sources which include operational and economical benefits. Random placement of DG sources in a distribution network will result in adverse effects such as increased power loss, loss of voltage stability and reliability, increase in operational costs, power quality issues etc. This paper presents a methodology to obtain the optimal location for the placement of multiple DG sources in a distribution network from a technical perspective. Optimal location is obtained by evaluating a global multi-objective technical index (MOTI) using a weighted sum method. Clonal selection based artificial immune system (AIS) is used along with optimal power flow (OPF) technique to obtain the solution. The proposed method is executed on a standard IEEE-33 bus radial distribution system. The results justify the choice of AIS and the use of MOTI in optimal siting of DG sources which improves the distribution system efficiency to a great extent in terms of reduced real and reactive power losses, improved voltage profile and voltage stability. Solutions obtained using AIS are compared with Genetic algorithm (GA) and Particle Swarm optimization (PSO) solutions for the same objective function.
Volume: 7
Issue: 2
Page: 641-649
Publish at: 2017-04-01

SC-FDM-IDMA Scheme Employing BCH Coding

10.11591/.v7i2.pp992-998
Roopali Agarwal , Manoj K. Shukla
In OFDM-IDMA scheme, intersymbol interference (ISI) is resolved by the OFDM layer and multiple access interference (MAI) is suppressed by the IDMA layer at low cost . However OFDM-IDMA scheme suffers high peak-to-average power ratio (PAPR) problem. For removing high PAPR problem a hybrid multiple access scheme SC-FDM-IDMA has been proposed. In this paper, bit error rate (BER) performance comparison of SC-FDM-IDMA scheme, OFDM-IDMA scheme and IDMA scheme have been duly presented.  Moreover, the BER performance of various subcarrier mapping methods for SC-FDM-IDMA scheme as well as other results with variation of different parameters have also been demonstrated. Finally simulation result for BER performance improvement has been shown employing BCH code. All the simulation results demonstrate the suitability of SC-FDM-IDMA scheme for wireless communication under AWGN channel environment.
Volume: 7
Issue: 2
Page: 992-998
Publish at: 2017-04-01

Utility Function-based Pricing Strategies in Maximizing the Information Service Provider’s Revenue with Marginal and Monitoring Costs

10.11591/.v7i2.pp877-887
Robinson Sitepu , Fitri Maya Puspita , Anggi Nurul Pratiwi , Icha Puspita Novyasti
Previous research only focus on maximizing revenue for pricing strategies for information good with regardless the marginal and monitoring costs. This paper aims to focus on the addition of marginal and monitoring costs into the pricing strategies to maintain the maximal revenue while introduce the costs incurred in adopting the strategies. The well-known utility functions applied to also consider the consumer’s satisfaction towards the service offered. The results show that the addition costs incurred for setting up the strategies can also increase the profit for the providers rather than neglecting the costs. It is also showed that the Cobb-Douglas utility functions used can enhance the notion of provider to optimize the revenue compared to quasi linear and perfect substitutes.
Volume: 7
Issue: 2
Page: 877-887
Publish at: 2017-04-01

The Correlation between Surface Tracking and Partial Discharge Characteristics on Pressboard Surface Immersed in MIDEL eN

10.11591/.v7i2.pp631-640
Nur Amirah Othman , Hidayat Zainuddin , Aminuddin Aman , Sharin Abd Ghani , Imran Sutan Chairul
This paper presents the investigation of the surface tracking on pressboard surface immersed in MIDEL eN oil.  In this work, the development of surface discharge was analyzed by correlating the visual records of surface tracking on impregnated pressboard and the partial discharge (PD) activities.  The PD activities during the surface tracking process were analyzed in terms of Phase Resolved Partial Discharge (PRPD) patterns.  Throughout the experiment, surface discharge is found as the development of tree-like patterns in the form of white marks occurring on the oil-pressboard interface.  This phenomenon is generally accepted as the drying out process that involves evaporation and decomposition of the oil molecules in the pressboard pores due to the surface discharge activities on the pressboard surface layer.  The development of surface discharge on the pressboard surface can continue from minutes to months or even years until failure.  Thus, condition monitoring system is important to characterize this type of faulty condition.  The experimental results show that there is the decreasing trend of PD magnitude during the development of white mark hallway of a gap distance which is eventually suffered from an unexpected fault.
Volume: 7
Issue: 2
Page: 631-640
Publish at: 2017-04-01

A Training Monitoring System for Cyclist Based on Wireless Sensor Networks

10.11591/ijeecs.v6.i1.pp80-87
N. M. Abdul Latiff , M. A. Ruslee , S. K. Syed Yusof , M. R. Abdul Rahim , H. Sayuti , K. Mohamad Yusof , M. A. Baharudin
This paper presents a training monitoring system for cyclist that is based on the technology of wireless sensor networks (WSNs). A stable and reliable wireless cyclist monitoring system is vital to establish a smart and efficient sports management program. A training monitoring system has been developed and tested in a real cyclist training environment in a velodrome. The system is designed is such a way that the packet loss rate is minimum. Using TelG mote as the basis, customized sensor nodes that function as a forwarder node and the relay nodes are developed to form the WSN. This WSN is linked to the cloud network on the Internet. The cloud network is then established and end users application for data accessing is designed. Several experiments have been conducted in a real scenario in a velodrome to measure the reliability of the system architecture. It is shown from the experiments that the proposed system is reliable even when the cyclist is moving at a high speed. The packet loss is less than 2% which does not give a huge impact to the data transmission.
Volume: 6
Issue: 1
Page: 80-87
Publish at: 2017-04-01

The Weights Detection of Multi-criteria by using Solver

10.11591/.v7i2.pp858-868
Fachrurrazi Fachrurrazi , Yuwaldi Away , Saiful Husin
Multi criteria, which are generally used for decision analysis, have certain characteristics that relate to the purpose of the decision. Multi criteria have complex structures and have different weights depending upon the consideration of assessors and the purpose of the decision also. Expert’s judgment will be used to detect the criteria weights that applied by assessors. The aim of this study is a model to detect the criteria weights and biases on the subcontractor selection and detecting the significant weights, as decisive criteria. A method, which is used to modeling the weights detection, is the Solver Application. Data, totaling 40 sets, has been collected that consist of the assessor’s assessment and the expert’s judgment. The result is a pattern of weights and biases detection. The proposed model have been able to detect of 20 criteria weights and biases, that consist of 4 criteria in  the total weights of 60% (as decisive criteria) and 16 criteria in the total weights of 40%. A model has been built by training process performed by the Solver, which the result for MSE training is 9.73711e-08 and for MSE validation is 0.00900528. Novelty in the study is a model to detect pattern of weights criteria and biases on subcontractor selection by transferring the expert's judgment using Solver Application.
Volume: 7
Issue: 2
Page: 858-868
Publish at: 2017-04-01

Implementation of Algorithm for Vehicle Anti-Collision Alert System in FPGA

10.11591/.v7i2.pp775-783
Aiman Zakwan Jidin , Lim Siau Li , Ahmad Fauzan Kadmin
Vehicle safety has becoming one of the important issues nowadays, due to the fact the number of road accidents, which cause injuries, deaths and also damages, keeps on increasing. One of the main factors which contribute to these accidents are human's lack of awareness and also carelessness. This paper presents the development and implementation of an algorithm to be utilized for vehicle anti-collision alert system, which may be useful to reduce the occurrence of accidents. This algorithm, which is to be deployed with the front sensors of the vehicle, is capable of alerting any occurrence of sudden slowing or static vehicles ahead, by sensing the rate of distance change. Furthermore, it also triggers an alert if the driver is breaching the safe distance from the vehicle ahead. This algorithm has been successfully implemented in Altera DE0 FPGA and its functionality was validated via hardware experimental tests.
Volume: 7
Issue: 2
Page: 775-783
Publish at: 2017-04-01

Maintenance and Safety Requirements of Flameproof and Intrinsically Safe Equipment for Coal Mines

10.11591/ijeecs.v6.i1.pp9-15
B. Ahirwal , Arvind kumar singh , Rajendra kumar vishwakarm
In the generation of the new technology segment, new explosionproof (Ex) equipment are being installed to make systems suitable for use in hazardous areas of mines. Generally, 80-90% equipment having flameproof (Exd) and intrinsic safety (Exi) methodology of protection are used in the mines for safe operation. The maintenance and safety are two vital parameters to improve the system efficiency of installation in the mines. These parameters are also responsible for the productivity of the mines. The minimum breakdown and maximum safety are the prime concerns of the mines to increase the production. Many observations and basic knowledge are necessary of safety parameters of Ex protections while doing maintenance because micro joules energy is sufficient to ignite the hazardous areas of mines. Trained and skilled personals having good knowledge of Ex protections are required to maintain the limitations of ignition energy sources of Ex equipment to prevent explosion in the mines. A regular and organized scheme of inspection and maintenance may ensure continued, satisfactory and safe operation of Ex electrical equipment in mines. The important points for safety and maintenance of Exd and Exi equipment are pondered in this paper.
Volume: 6
Issue: 1
Page: 9-15
Publish at: 2017-04-01
Show 1673 of 2098

Discover Our Library

Embark on a journey through our expansive collection of articles and let curiosity lead your path to innovation.

Explore Now
Library 3D Ilustration